CT Angiography in the Lower Extremity Peripheral Artery Disease Feasibility of an Ultra-Low Volume Contrast Media Protocol.
Cardiovasc Intervent Radiol
; 41(11): 1751-1764, 2018 Nov.
Article
en En
| MEDLINE
| ID: mdl-29789875
PURPOSE: The ALARA principle is not only relevant for effective dose (ED) reduction, but also applicable for contrast media (CM) management. Therefore, the aim was to evaluate the feasibility of an ultra-low CM protocol in the assessment of peripheral artery disease (PAD). MATERIALS AND METHODS: Fifty PAD patients were scanned on third-generation dual-source computed tomography, from diaphragm to the forefoot, as follows: tube voltage: 70 kV, reference effective tube current: 90 mAs, collimation: 192 × 2 × 0.6 mm, with individualized acquisition timing. The protocol ED (mSv) was quantified with dedicated software. CM protocol consisted of 15 ml test bolus and 30 ml main bolus (300 mgI/ml) injected at 5 ml/s, followed by a 40 ml saline chaser at the same flow rate. Aorto-popliteal bolus transit time was used to calculate the overall acquisition time and delay. Objective (hounsfield units-HU; contrast-to-noise ratio-CNR) and subjective image quality (four-point Likert score) were assessed at different anatomical regions from the aorta down to the forefoot. RESULTS: Mean attenuation values were exceeding 250 HU from aorta down to the anterior tibial artery with CNR < 13. However, decline in attenuation was observed in more distal region with mean values of 165 and 199 HU, in left and right dorsalis pedis artery, respectively. Mode subjective image quality from the level of aorta down to the popliteal segment was excellent; below the knee mode score was good. The mean ED per protocol was 1.1 ± 0.5 mSv. CONCLUSION: Use of an ultra-low CM volume protocol at 70 kV is feasible in the evaluation of PAD, resulting in good to excellent image quality with mean ED of 1.1 ± 0.5 mSv. LEVEL OF EVIDENCE: Level 3, Local non-random sample.
Palabras clave
Texto completo:
1
Bases de datos:
MEDLINE
Asunto principal:
Medios de Contraste
/
Extremidad Inferior
/
Enfermedad Arterial Periférica
/
Angiografía por Tomografía Computarizada
Límite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Cardiovasc Intervent Radiol
Año:
2018
Tipo del documento:
Article
País de afiliación:
Países Bajos