Your browser doesn't support javascript.
loading
Validity and reliability of a novel optoelectronic device to measure movement velocity, force and power during the back squat exercise.
Laza-Cagigas, Roberto; Goss-Sampson, Mark; Larumbe-Zabala, Eneko; Termkolli, Leke; Naclerio, Fernando.
Afiliación
  • Laza-Cagigas R; a Department of Life and Sport Science , University of Greenwich , New Eltham , UK.
  • Goss-Sampson M; a Department of Life and Sport Science , University of Greenwich , New Eltham , UK.
  • Larumbe-Zabala E; b Clinical Research Institute , Texas Tech University HSC , Lubbock , TX , USA.
  • Termkolli L; a Department of Life and Sport Science , University of Greenwich , New Eltham , UK.
  • Naclerio F; a Department of Life and Sport Science , University of Greenwich , New Eltham , UK.
J Sports Sci ; 37(7): 795-802, 2019 Apr.
Article en En | MEDLINE | ID: mdl-30306839
ABSTRACT
This study analysed the validity and reliability of a new optoelectronic device (Velowin) for the measurement of vertical displacement and velocity as well as to estimate force and mechanical power. Eleven trained males with Mean (SD) age = 27.4 (4.8) years, completed an incremental squat exercise test with 5 different loads (<30-90% of their 1-repetition maximum) while displacement and vertical velocity of the barbell were simultaneously measured using an integrated 3D system (3D motion capture system + force platform) and Velowin. Substantial to almost perfect correlation (concordance correlation coefficient = 0.75-0.96), root mean square error as coefficient of variation ±90% confidence interval ≤10% and good to excellent intraclass correlation coefficient = 0.84-0.99 were determined for all the variables. Passing and Bablock regression methods revealed no differences for average velocity. However, significant but consistent bias were determined for average or peak force and power while systematic and not proportional bias was found for displacement. In conclusion, Velowin, in holds of some potential advantages over traditionally used accelerometer or linear transducers, represents a valid and reliable alternative to monitor vertical displacement and velocity as well as to estimate average force and mechanical power during the squat exercise.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Entrenamiento de Fuerza / Acelerometría / Movimiento Límite: Adult / Humans / Male Idioma: En Revista: J Sports Sci Año: 2019 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Entrenamiento de Fuerza / Acelerometría / Movimiento Límite: Adult / Humans / Male Idioma: En Revista: J Sports Sci Año: 2019 Tipo del documento: Article País de afiliación: Reino Unido