Validation of Quantitative 3-Dimensional Transesophageal Echocardiography Mitral Valve Analysis Using Stereoscopic Display.
J Cardiothorac Vasc Anesth
; 33(3): 732-741, 2019 03.
Article
en En
| MEDLINE
| ID: mdl-30340952
OBJECTIVE: The use of 3-dimensional (3D) transesophageal echocardiography (TEE) in perioperative evaluation of the mitral valve (MV) is increasing progressively, including the use of 3D MV models for quantitative analysis. However, the use of 3D MV models in clinical practice still is limited by the need for specific training and the long time required for analysis. A new stereoscopic visualization tool (EchoPixel True 3D) allows virtual examination of anatomic structures in the clinical setting, but its accuracy and feasibility for intraoperative use is unknown. The aim of this study was to assess the feasibility of 3D holographic display and evaluate 3D quantitative measurements on a volumetric MV image using the EchoPixel system compared with the 3D MV model generated by QLAB Mitral Valve Navigation (MVN) software. DESIGN: This was a retrospective comparative study. SETTING: The study took place in a tertiary care center. PARTICIPANTS: A total of 40 patients, 20 with severe mitral regurgitation who underwent mitral valve repair and 20 controls with normal MV, were enrolled retrospectively. INTERVENTIONS: The 3D-TEE datasets of the MV were analyzed using a 3D MV model and stereoscopic display. The agreement of measurements, intraobserver and interobserver variability, and time for analysis were assessed. MEASUREMENTS AND MAIN RESULTS: Fair agreement between the 2 software systems was found for annular circumference and area in pathologic valves, but good agreement was reported for prolapse height and linear annular diameters. A higher agreement for all annular parameters and prolapse height was seen in normal valves. Excellent intraobserver and interobserver reliability was proved for the same parameters; time for analysis between the 2 methods in pathologic valves was substantially equivalent, although longer in pathologic valves when compared with normal MV using both tools. CONCLUSION: EchoPixel proved to be reliable to display 3D TEE datasets and accurate for direct linear measurement of both MV annular sizes and prolapse height compared to QLAB MVN software; it also carries a low interobserver and intraobserver variability for most measurements.
Palabras clave
Texto completo:
1
Bases de datos:
MEDLINE
Asunto principal:
Holografía
/
Ecocardiografía Transesofágica
/
Ecocardiografía Tridimensional
/
Insuficiencia de la Válvula Mitral
Tipo de estudio:
Observational_studies
/
Prognostic_studies
Límite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
J Cardiothorac Vasc Anesth
Asunto de la revista:
ANESTESIOLOGIA
/
CARDIOLOGIA
Año:
2019
Tipo del documento:
Article
País de afiliación:
Italia