Your browser doesn't support javascript.
loading
Systematic Screening Using Luminex for De Novo C3d Fixing of Class II Donor-Specific Antibodies Is Correlated With Luminex Mean Fluorescence Intensity in Renal Transplant Patients.
Villemaire, Morgane; Jouve, Thomas; Bourdin, Anne; Janbon, Bénédicte; Pinel, Nicole; Tetaz, Rachel; Terrier, Nicolas; Rostaing, Lionel; Masson, Dominique; Malvezzi, Paolo.
Afiliación
  • Villemaire M; From the Service de Néphrologie, Hémodialyse, Aphérèses et Transplantation, Centre Hospitalier Universitaire (CHU) Grenoble-Alpes, Grenoble, France.
Exp Clin Transplant ; 17(4): 483-489, 2019 08.
Article en En | MEDLINE | ID: mdl-30346267
ABSTRACT

OBJECTIVES:

Chronic antibody-mediated rejection is the main cause of late kidney graft loss. The presence of donor-specific antibodies in the serum is the main criterion for this diagnosis. Single antigen Luminex assays can identify donor-specific antibodies, and semiquantitative estimates of antibodies can be assessed using mean fluorescence intensity. Recent data have shown that patients whose donor-specific antibodies fix C3d have worse clinical outcomes, implying that C3d-specific Luminex assays may provide useful prognostic data. MATERIALS AND

METHODS:

We compared C3d donor-specific antibodies with standard immunoglobulin G donor-specific antibody mean fluorescence intensities in a cohort of patients with de novo class II donor-specific antibodies and analyzed subsequent graft survival. The included kidney graft recipients received transplants between 2005 and 2015 and had developed de novo class II donor-specific antibodies. Serum was tested using the standard single antigen Luminex technique and the C3d-fixing antibody-detection system (Immucor, Herentals, Belgium).

RESULTS:

In our patient cohort, 41/924 patients (4.4%) developed class II donor-specific antibodies, and 65 serum samples were analyzed (at baseline and follow-up). Among these samples, 43 (66%) were negative for C3d donor-specific antibodies. A mean fluorescence intensity threshold of 9000 in the single antigen Luminex assay discerned all negative (from positive) C3d donor-specific antibodies, even when all single-bead results were taken into account. Sixteen patients (39%) had poor outcomes (ie, either creatinine levels had doubled or they had lost their graft) over the median follow-up of 5 years. C3d results were significantly associated with graft survival (P = .04). We found a strong correlation between C3d-fixing antibody positivity and mean fluorescence intensity strength in the setting of de novo class II donor-specific antibodies.

CONCLUSIONS:

These results further reinforce the paradigm that the higher the mean fluorescence intensity, the more complement activation occurs. Routine C3d testing is thus unnecessary in this setting.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Pruebas de Fijación del Complemento / Complemento C3d / Trasplante de Riñón / Inmunidad Humoral / Rechazo de Injerto / Supervivencia de Injerto / Antígenos HLA / Isoanticuerpos Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Exp Clin Transplant Asunto de la revista: TRANSPLANTE Año: 2019 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Pruebas de Fijación del Complemento / Complemento C3d / Trasplante de Riñón / Inmunidad Humoral / Rechazo de Injerto / Supervivencia de Injerto / Antígenos HLA / Isoanticuerpos Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Exp Clin Transplant Asunto de la revista: TRANSPLANTE Año: 2019 Tipo del documento: Article País de afiliación: Francia