Your browser doesn't support javascript.
loading
A Quantitative Tandem Mass Spectrometry and Scaled-Down QuEChERS Approach for Simultaneous Analysis of Pesticide Multiresidues in Human Urine.
Shin, Yongho; Lee, Jiho; Park, Eunyoung; Lee, Junghak; Lee, Hye Suk; Kim, Jeong-Han.
Afiliación
  • Shin Y; Pesticide Chemistry and Toxicology Laboratory, Department of Agricultural Biotechnology and Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul 08826, Korea. driger6103@catholic.ac.kr.
  • Lee J; Drug Metabolism and Bioanalysis Laboratory, College of Pharmacy, The Catholic University of Korea, Bucheon-si, Gyeonggi-do 14662, Korea. driger6103@catholic.ac.kr.
  • Park E; Pesticide Chemistry and Toxicology Laboratory, Department of Agricultural Biotechnology and Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul 08826, Korea. micai1@snu.ac.kr.
  • Lee J; Pesticide Chemistry and Toxicology Laboratory, Department of Agricultural Biotechnology and Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul 08826, Korea. pey4321@snu.ac.kr.
  • Lee HS; Pesticide Chemistry and Toxicology Laboratory, Department of Agricultural Biotechnology and Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul 08826, Korea. crane245@snu.ac.kr.
  • Kim JH; Drug Metabolism and Bioanalysis Laboratory, College of Pharmacy, The Catholic University of Korea, Bucheon-si, Gyeonggi-do 14662, Korea. kjh2404@snu.ac.kr.
Molecules ; 24(7)2019 Apr 04.
Article en En | MEDLINE | ID: mdl-30987340
Multiresidual pesticide determination in a biological sample is essential for an immediate decision and response related to various pesticide intoxications. A rapid and simultaneous analytical method for 260 pesticides in human urine was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). High speed positive/negative switching electrospray ionization (ESI) mode was used, and scheduled multiple reaction monitoring (MRM) was optimized. Three versions of scaled-down QuEChERS procedures were evaluated, and the procedure using non-buffer reagents (magnesium sulfate and sodium chloride) and excluding cleanup steps was selected for optimum pesticide extraction. The limit of quantitation (LOQ) in this methodology was 10 ng/mL for each target pesticide, and correlation coefficient (r²) values of calibration curves were ≥0.988 (linearity range; 10-250 ng/mL). In accuracy and precision tests, the relative error ranges were -18.4% to 19.5%, with relative standard deviation (RSD) 2.1%-19.9% at an LOQ level (10 ng/mL), and -14.7% to 14.9% (RSD; 0.6%-14.9%) at higher concentrations (50, 150, and 250 ng/mL). Recovery range was 54.2%-113.9% (RSD; 0.3%-20.0%), and the soft matrix effect (range; -20% to 20%) was observed in 75.4% of target pesticides. The established bioanalytical methods are sufficient for application to biomonitoring in agricultural exposures and applicable in the forensic and clinic.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Residuos de Plaguicidas / Cromatografía Liquida / Urinálisis / Espectrometría de Masas en Tándem Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Molecules Asunto de la revista: BIOLOGIA Año: 2019 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Residuos de Plaguicidas / Cromatografía Liquida / Urinálisis / Espectrometría de Masas en Tándem Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Molecules Asunto de la revista: BIOLOGIA Año: 2019 Tipo del documento: Article