Your browser doesn't support javascript.
loading
Microplastic analysis-are we measuring the same? Results on the first global comparative study for microplastic analysis in a water sample.
Müller, Yanina K; Wernicke, Theo; Pittroff, Marco; Witzig, Cordula S; Storck, Florian R; Klinger, Josef; Zumbülte, Nicole.
Afiliación
  • Müller YK; TZW: DVGW-Technologiezentrum Wasser (German Water Centre), Karlsruher Str. 84, 76139, Karlsruhe, Germany.
  • Wernicke T; TZW: DVGW-Technologiezentrum Wasser (German Water Centre), Karlsruher Str. 84, 76139, Karlsruhe, Germany.
  • Pittroff M; UFZ-Helmholtz Centre for Environmental Research, 04318, Leipzig, Germany.
  • Witzig CS; TZW: DVGW-Technologiezentrum Wasser (German Water Centre), Karlsruher Str. 84, 76139, Karlsruhe, Germany.
  • Storck FR; TZW: DVGW-Technologiezentrum Wasser (German Water Centre), Karlsruher Str. 84, 76139, Karlsruhe, Germany.
  • Klinger J; TZW: DVGW-Technologiezentrum Wasser (German Water Centre), Karlsruher Str. 84, 76139, Karlsruhe, Germany.
  • Zumbülte N; Federal Office for the Environment FOEN (Hydrology Division), 3003, Bern, Switzerland.
Anal Bioanal Chem ; 412(3): 555-560, 2020 Jan.
Article en En | MEDLINE | ID: mdl-31848670
This paper presents the results of the first international comparative study of commonly applied analytical methods for microplastic analysis. Although it was shown that the comparability between previously published studies is highly limited, there are ambitious efforts regarding the standardization of microplastic analysis. This comparative study serves as a first step to assess the suitability of frequently used methods in microplastic research. Furthermore, it highlights obstacles when conducting a comparative study for microplastics. Results from 17 laboratories from eight different countries are compared. Samples comprised of five different types of microplastic reference particles with diameters ranging from 8 µm to 140 µm suspended in ultrapure water. Microscopy, Fourier-transform infrared microspectroscopy (µ-FTIR), Raman microspectroscopy (µ-Raman), thermo-extraction-and-desorption- or pyrolysis- combined with gas chromatography coupled to mass spectrometry (Σ-GC/MS), scanning electron microscopy and particle counter were compared regarding results on total particle number, polymer type, number of particles and/or particle mass for each polymer type. In the scope of this comparative study, for the identification of polymer type µ-Raman and Σ-GC/MS performed best. The quantification of polymer mass for identified polymer types was questionable for Σ-GC/MS, whereas other methods failed to determine the correct polymer mass. Quantification of particle number per identified polymer type was evaluated successful for µ-FTIR and the quantification of total particle numbers was best for microscopy and to a lesser extent for µ-FTIR. Remarkable was the large variance of results between the methods but also within the methods. The latter is likely due to individual interpretations of methods and preparation protocols, in particular in regard to the handling of blank values. Results strongly emphasize the need for standardization and validation of analytical methods in microplastic research both on a global scale as well as in the context of individual laboratories.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Anal Bioanal Chem Año: 2020 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Anal Bioanal Chem Año: 2020 Tipo del documento: Article País de afiliación: Alemania