Your browser doesn't support javascript.
loading
Validated Computational Framework for Evaluation of In Vivo Knee Mechanics.
Ali, Azhar A; Mannen, Erin M; Rullkoetter, Paul J; Shelburne, Kevin B.
Afiliación
  • Ali AA; Stryker Orthopaedics, 325 Corporate Drive, Mahwah, NJ 07430.
  • Mannen EM; Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR 72207.
  • Rullkoetter PJ; Center for Orthopaedic Biomechanics, Department of Mechanical and Materials Engineering, The University of Denver, 2155 East Wesley Avenue, Denver, CO 80208.
  • Shelburne KB; Center for Orthopaedic Biomechanics, Department of Mechanical and Materials Engineering, The University of Denver, 2155 East Wesley Avenue, Denver, CO 80208.
J Biomech Eng ; 142(8)2020 08 01.
Article en En | MEDLINE | ID: mdl-31913450
ABSTRACT
Dynamic, in vivo evaluations of knee mechanics are important for understanding knee injury and repair, and developing successful treatments. Computational models have been used with in vivo experiments to quantify joint mechanics, but they are typically not predictive. The current study presents a novel integrated approach with high-speed stereo radiography, musculoskeletal modeling, and finite element (FE) modeling for evaluation of subject-specific, in vivo knee mechanics in a healthy subject performing a seated knee extension and weight-bearing lunge. Whole-body motion capture, ground reaction forces, and radiography-based kinematics were used to drive musculoskeletal and predictive FE models for load-controlled simulation of in vivo knee mechanics. A predictive simulation of knee mechanics was developed in four stages (1) in vivo measurements of one subject performing a lunge and a seated knee extension, (2) rigid-body musculoskeletal modeling to determine muscle forces, (3) FE simulation of knee extension for knee-ligament calibration, and (4) predictive FE simulation of a lunge. FE models predicted knee contact and ligament mechanics and evaluated the impact of cruciate ligament properties on joint kinematics and loading. Calibrated model kinematics demonstrated good agreement to the experimental motion with root-mean-square differences of tibiofemoral flexion-extension <3 deg, internal-external <4 deg, and anterior-posterior <2 mm. Ligament reference strain and attachment locations were the most critical properties in the calibration process. The current work advances previous in vivo knee modeling through simulation of dynamic activities, modeling of subject-specific knee behavior, and development of a load-controlled knee model.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Análisis de Elementos Finitos / Articulación de la Rodilla Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: J Biomech Eng Año: 2020 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Análisis de Elementos Finitos / Articulación de la Rodilla Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: J Biomech Eng Año: 2020 Tipo del documento: Article