Your browser doesn't support javascript.
loading
PtNPs-GNPs-MWCNTs-ß-CD nanocomposite modified glassy carbon electrode for sensitive electrochemical detection of folic acid.
Yuan, Meng-Meng; Zou, Jiao; Huang, Zhao-Ning; Peng, Dong-Ming; Yu, Jin-Gang.
Afiliación
  • Yuan MM; College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, Hunan, China.
  • Zou J; College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, Hunan, China.
  • Huang ZN; College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, Hunan, China.
  • Peng DM; School of Pharmacy, Hunan University of Chinese Medicine, Changsha, 410208, Hunan, China. pdmcsu@126.com.
  • Yu JG; College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, Hunan, China. yujg@csu.edu.cn.
Anal Bioanal Chem ; 412(11): 2551-2564, 2020 Apr.
Article en En | MEDLINE | ID: mdl-32162086
A novel electrochemical sensor, platinum nanoparticles/graphene nanoplatelets/multi-walled carbon nanotubes/ß-cyclodextrin composite (PtNPs-GNPs-MWCNTs-ß-CD) modified carbon glass electrode (GCE), was fabricated and used for the sensitive detection of folic acid (FA). The PtNPs-GNPs-MWCNTs-ß-CD nanocomposite was easily prepared with an ultrasound-assisted assembly method, and it was characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The electrochemical behavior of FA at PtNPs-GNPs-MWCNTs-ß-CD/GCE was investigated in detail. Some key experimental parameters such as pH, amount of PtNPs-GNPs-MWCNTs-ß-CD composite, and scan rate were optimized. A good linear relationship (R2 = 0.9942) between peak current of cyclic voltammetry (CV) and FA concentration in the range 0.02-0.50 mmol L-1 was observed at PtNPs-GNPs-MWCNTs-ß-CD/GCE. The detection limit was 0.48 µmol L-1 (signal-to-noise ratio = 3). A recovery of 97.55-102.96% was obtained for the determination of FA in FA pills (containing 0.4 mg FA per pill) at PtNPs-GNPs-MWCNTs-ß-CD/GCE, indicating that the modified electrode possessed relatively high sensitivity and stability for the determination of FA in real samples.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Platino (Metal) / Complejo Vitamínico B / Nanotubos de Carbono / Nanocompuestos / Técnicas Electroquímicas / Ácido Fólico Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Año: 2020 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Platino (Metal) / Complejo Vitamínico B / Nanotubos de Carbono / Nanocompuestos / Técnicas Electroquímicas / Ácido Fólico Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Año: 2020 Tipo del documento: Article País de afiliación: China