Your browser doesn't support javascript.
loading
Efficient removal of triclosan via peroxymonosulfate activated by a ppb level dosage of Co(II) in water: Reaction kinetics, mechanisms and detoxification.
Peng, Jianbiao; Zhang, Chaonan; Zhang, Yaozong; Shao, Shuai; Wang, Pingping; Liu, Guoguang; Dong, Hang; Liu, Dexin; Shi, Jialu; Cao, Zhiguo; Liu, Haijin; Gao, Shixiang.
Afiliación
  • Peng J; School of Environment, Henan Normal University, Key Laboratory for Yellow River and Huai River Water Environmental and Pollution Control, Ministry of Education, Henan Key Laboratory for Environmental Pollution Control, Xinxiang, 453007, PR China. Electronic address: 2017069@htu.edu.cn.
  • Zhang C; School of Environment, Henan Normal University, Key Laboratory for Yellow River and Huai River Water Environmental and Pollution Control, Ministry of Education, Henan Key Laboratory for Environmental Pollution Control, Xinxiang, 453007, PR China.
  • Zhang Y; School of Environment, Henan Normal University, Key Laboratory for Yellow River and Huai River Water Environmental and Pollution Control, Ministry of Education, Henan Key Laboratory for Environmental Pollution Control, Xinxiang, 453007, PR China.
  • Shao S; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, 210023, PR China.
  • Wang P; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, 210023, PR China.
  • Liu G; School of Environmental Science and Engineering, and Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou, 510006, PR China. Electronic address: liugg@gdut.edu.cn.
  • Dong H; Department of Chemical Engineering, Stanford University, Stanford, CA, 94305, USA.
  • Liu D; College of Environment and Planning, Henan University, Kaifeng, 475004, PR China.
  • Shi J; School of Environment, Henan Normal University, Key Laboratory for Yellow River and Huai River Water Environmental and Pollution Control, Ministry of Education, Henan Key Laboratory for Environmental Pollution Control, Xinxiang, 453007, PR China.
  • Cao Z; School of Environment, Henan Normal University, Key Laboratory for Yellow River and Huai River Water Environmental and Pollution Control, Ministry of Education, Henan Key Laboratory for Environmental Pollution Control, Xinxiang, 453007, PR China.
  • Liu H; School of Environment, Henan Normal University, Key Laboratory for Yellow River and Huai River Water Environmental and Pollution Control, Ministry of Education, Henan Key Laboratory for Environmental Pollution Control, Xinxiang, 453007, PR China.
  • Gao S; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, 210023, PR China.
Ecotoxicol Environ Saf ; 198: 110676, 2020 Jul 15.
Article en En | MEDLINE | ID: mdl-32361496
ABSTRACT
Triclosan (TCS), an extensively used broad-spectrum antimicrobial agent, has raised significant environmental concerns regarding its widespread occurrence in waters. In this study, the removal of TCS in aqueous solution via peroxymonosulfate (PMS) activated by an extremely low-level Co2+ (0.02 µM) was systematically investigated. During preliminary test, TCS (10 µM) was totally degraded in 30 min by using 0.1 µM Co2+ and 40 µM PMS at pH 7.0 with a degradation rate constant of 0.1219 min-1. A first-order apparent degradation rate of TCS was found with respect to the PMS concentrations. At extremely low dosage of Co2+ (0.02 µM), the presence of NO3-, HCO3-, PLFA, and SRHA within test concentrations significantly inhibited TCS removal, while a dual effect of Cl- on the degradation rate of TCS was observed. The quenching experiments verified that SO4- was the dominant reactive oxygen species (ROS) rather than OH. Six major intermediates were identified using TOF-LC-MS, based on which we proposed three associated reaction pathways including hydroxylation, ether bond breakage, and dechlorination. Toxicity predictions by ECOSAR software exhibited aquatic toxicity reduction of TCS after Co2+/PMS treatment. We outlook these findings to advance the feasibility of organic contaminants removal via Co2+/PMS system with Co2+ at extremely low levels.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Peróxidos / Triclosán / Contaminantes Químicos del Agua / Cobalto / Purificación del Agua Tipo de estudio: Prognostic_studies Idioma: En Revista: Ecotoxicol Environ Saf Año: 2020 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Peróxidos / Triclosán / Contaminantes Químicos del Agua / Cobalto / Purificación del Agua Tipo de estudio: Prognostic_studies Idioma: En Revista: Ecotoxicol Environ Saf Año: 2020 Tipo del documento: Article