Your browser doesn't support javascript.
loading
Clinical validity of two different grading systems for lumbar central canal stenosis: Schizas and Lee classification systems.
Ko, Yeon-Jee; Lee, Eugene; Lee, Joon Woo; Park, Chi Young; Cho, Jungheum; Kang, Yusuhn; Ahn, Joong Mo.
Afiliación
  • Ko YJ; Departments of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
  • Lee E; Departments of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
  • Lee JW; Departments of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
  • Park CY; Departments of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
  • Cho J; Departments of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
  • Kang Y; Departments of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
  • Ahn JM; Departments of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
PLoS One ; 15(5): e0233633, 2020.
Article en En | MEDLINE | ID: mdl-32459814
ABSTRACT

OBJECTIVE:

To assess the learnability of two magnetic resonance imaging (MRI) grading systems for lumbar central canal stenosis based on inter-observer agreement and test-retest reliability of doctors with no prior knowledge of the two systems. MATERIALS AND

METHODS:

Two clinical fellows, one novice radiology resident, one neurosurgeon, and one orthopedic surgeon, who were unaware of the two qualitative MRI grading systems prior to this study, acquainted themselves with the teaching files. All five observers independently assessed the LCCS grade of 70 patients using T2-weighted axial magnetic resonance images at the L2-3, L3-4, L3-4, and L5-S1 disc levels. Analysis was performed twice at an interval of two months.

RESULTS:

The inter-observer agreement among all five readers was excellent and test-retest reliability was moderate to excellent for both the Schizas and Lee systems. Positive percentage agreements were found to be over 0.8 in almost all observers with relatively narrow 95% confidence limits.

CONCLUSION:

Both Schizas and Lee MRI grading systems for LCCS are reliable grading systems, and can be used as a learnable method for both clinicians and radiologists.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Estenosis Espinal / Índice de Severidad de la Enfermedad / Imagen por Resonancia Magnética / Disco Intervertebral / Vértebras Lumbares Tipo de estudio: Qualitative_research Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2020 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Estenosis Espinal / Índice de Severidad de la Enfermedad / Imagen por Resonancia Magnética / Disco Intervertebral / Vértebras Lumbares Tipo de estudio: Qualitative_research Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2020 Tipo del documento: Article