Your browser doesn't support javascript.
loading
A new self-designed "tongue root holder" device to aid fiberoptic intubation.
Cao, Xiaofei; Wu, Junbei; Fang, Yin; Ding, Zhengnian; Qi, Tao.
Afiliación
  • Cao X; Department of Anesthesiology, The First Affiliated Hospital with Nanjing Medical University, 300 Guangzhou Road, Nanjing, 210029, People's Republic of China.
  • Wu J; Department of Anesthesiology, The First Affiliated Hospital with Nanjing Medical University, 300 Guangzhou Road, Nanjing, 210029, People's Republic of China.
  • Fang Y; Department of Anesthesiology, The First Affiliated Hospital with Nanjing Medical University, 300 Guangzhou Road, Nanjing, 210029, People's Republic of China.
  • Ding Z; Department of Anesthesiology, The First Affiliated Hospital with Nanjing Medical University, 300 Guangzhou Road, Nanjing, 210029, People's Republic of China. dingzhengnian@yeah.net.
  • Qi T; Department of Anesthesiology, The First Affiliated Hospital with Nanjing Medical University, 300 Guangzhou Road, Nanjing, 210029, People's Republic of China. taoqinjmu@hotmail.com.
Clin Oral Investig ; 24(12): 4335-4342, 2020 Dec.
Article en En | MEDLINE | ID: mdl-32748071
ABSTRACT

OBJECTIVE:

In this study, we aimed to assess the feasibility of fiberoptic intubation (FOI), using a new, self-designed, "tongue root holder" device, in combination with the jaw thrust maneuver.

METHODS:

Three hundred patients undergoing elective surgery requiring orotracheal intubation were enrolled. Patients presented at least one or more risk factors for difficult airway. The patients were randomly allocated at a 11 ratio to one of two groups group L, FOI with tongue root holder, or group C, standard FOI. Orotracheal FOI was performed after commencement of anesthesia. The jaw thrust maneuver was applied in both groups to facilitate advancement of the fiberoptic bronchoscope. The primary endpoint was the feasibility of FOI. The secondary endpoints were number of attempts, time to intubation, and airway clearance at the soft palate and epiglottis levels.

RESULTS:

The FOI was achieved in all 150 patients in group L, significantly higher than that in group C (100% vs 95.3%; P = 0.015). Less attempts of intubation were made in group L (P = 0.039). Mean time to successful intubation on the first attempt was shorter in group L (P < 0.001). The mean times to view the vocal cord and carina were also shorter in group L (P = 0.011 and P < 0.001, respectively). Airway clearance was better in group L at both the soft palate and the glottis levels (P = 0.010 and P = 0.038, respectively).

CONCLUSIONS:

This study shows that FOI is feasible with the newly introduced, self-designed, "tongue root holder" device, when combined with the jaw thrust maneuver in patients with risk factors for difficult airway. The device also provides better airway clearance, less intubation attempts, and shorter time to intubation at first attempt. CLINICAL RELEVANCE Fiberoptic bronchoscope has been the gold standard for routine management of difficult airway. A technique to open the airway is introduced to reduce the incidence rate of upper airway obstruction.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tecnología de Fibra Óptica / Intubación Intratraqueal Tipo de estudio: Clinical_trials / Etiology_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Clin Oral Investig Asunto de la revista: ODONTOLOGIA Año: 2020 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tecnología de Fibra Óptica / Intubación Intratraqueal Tipo de estudio: Clinical_trials / Etiology_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Clin Oral Investig Asunto de la revista: ODONTOLOGIA Año: 2020 Tipo del documento: Article