Your browser doesn't support javascript.
loading
Etiology of syncope in patients with preexisting atrioventricular conduction disorders.
Mitro, Peter; Simurda, Milos; Lazúrová, Zora; Jakubová, Marta.
Afiliación
  • Mitro P; Cardiology Clinic, Safarik University, VUSCH, Kosice, Slovakia.
  • Simurda M; Cardiology Clinic, Safarik University, VUSCH, Kosice, Slovakia.
  • Lazúrová Z; Cardiology Clinic, Safarik University, VUSCH, Kosice, Slovakia.
  • Jakubová M; Cardiology Clinic, Safarik University, VUSCH, Kosice, Slovakia.
Pacing Clin Electrophysiol ; 43(11): 1268-1272, 2020 11.
Article en En | MEDLINE | ID: mdl-32901951
ABSTRACT

BACKGROUND:

The discussion about the feasibility of empiric pacemaker implantation in patients with preexisting atrioventricular (AV) conduction disorders continues. The aim of the study was to determine the etiology of syncope and the need for pacemaker insertion in patients with AV conduction impairment using implantable loop recorder (ILR).

METHODS:

ILR was implanted after negative diagnostic workup in 37 patients with syncope (24 men, 13 women, age 72 ± 10 years) and preexisting impairment of AV conduction. First-degree AV block (AVB I) was present in 26 patients, and bundle branch block (BBB) in 17 patients.

RESULTS:

ILR-based diagnosis was made in 28 patients (75%)-sinus arrest in 13 patients, complete AVB in 10 patients, and vasodepressor syncope in five patients. In patients with preexisting BBB, sinus arrest occurred during ILR monitoring significantly more frequently than in patients without BBB (53% vs 20%, P = .03). Complete AVB was significantly less common in patients with preexisting BBB than in patients without BBB (12% vs 40%, P = .04). On multivariate regression analysis, the only independent predictor of AVB occurrence during ILR monitoring was preexisting AVB I (P = .03). The only independent predictor of sinus arrest during ILR monitoring was preexisting BBB (P = .03).

CONCLUSIONS:

In patients with preexisting AV conduction disorders, prevailing syncopal mechanism during ILR monitoring was asystole. However, sinus arrest occurred more often than complete AVB and was predicted by preexisting BBB. Preexisting AVB was a predictor of complete AVB during ILR monitoring.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Marcapaso Artificial / Síncope / Bloqueo Atrioventricular Tipo de estudio: Etiology_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Pacing Clin Electrophysiol Año: 2020 Tipo del documento: Article País de afiliación: Eslovaquia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Marcapaso Artificial / Síncope / Bloqueo Atrioventricular Tipo de estudio: Etiology_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Pacing Clin Electrophysiol Año: 2020 Tipo del documento: Article País de afiliación: Eslovaquia