Your browser doesn't support javascript.
loading
Prediction of Birth Weight and Neonatal Adiposity Using Ultrasound Assessment of Soft Tissue Parameters in Addition to Two-Dimensional Conventional Biometry.
Garcia Flores, Jose; Mogra, Ritu; Sadowski, Monica; Hyett, Jon.
Afiliación
  • Garcia Flores J; Sydney Institute for Women, Children and Their Families, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia.
  • Mogra R; Sydney Institute for Women, Children and Their Families, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia, Ritu.Mogra@health.nsw.gov.au.
  • Sadowski M; Discipline of Obstetrics, Gynaecology and Neonatology, Faculty of Medicine, University of Sydney, Sydney, New South Wales, Australia, Ritu.Mogra@health.nsw.gov.au.
  • Hyett J; Sydney Institute for Women, Children and Their Families, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia.
Fetal Diagn Ther ; 48(3): 201-208, 2021.
Article en En | MEDLINE | ID: mdl-33657569
ABSTRACT

INTRODUCTION:

We aim to evaluate the supplementary predictive value of soft tissue markers, including fetal limb volumes, for fetal birth weight and fat tissue weight.

METHODS:

This is a prospective study of 60 patients undergoing term induction of labor. Ultrasound was performed 48 h before birth, and 2D sonographic measurements, subcutaneous tissue thickness, and 3D fetal limb volumes were taken. Birth weight and neonatal fat weight were assessed by plethysmography. Clinical data were collected. The relation between ultrasound and neonatal outcomes was assessed by univariate and multivariate predictive models. The estimated and actual birth weights were compared applying different published formulas, and systematic and random error were collected and compared.

RESULTS:

3D fetal limb volumes showed a strong relation to birth weight, absolute weight, and relative fat weight. The Lee 6 formula performed better than either Hadlock 3 or Lee 3 with the lowest random error. Fractional limb volumes involve a highly reproducible technique, with excellent correlation (intra-class coefficient >0.90) for both inter- and intra-observer reliability. The prevalence of estimated EFW measures within 10% error from the actual birth weight was 71.7% with the Hadlock 3 model and 95.0% with the Lee 6 model (p = 0.09).

CONCLUSION:

Late assessment of 3D fetal limb volume in upper and lower extremities is not only useful for accurately predicting birth weight but is a useful marker for prediction of birth fat tissue weight.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ultrasonografía Prenatal / Adiposidad Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Newborn / Pregnancy Idioma: En Revista: Fetal Diagn Ther Asunto de la revista: DIAGNOSTICO POR IMAGEM / OBSTETRICIA / PERINATOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ultrasonografía Prenatal / Adiposidad Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Newborn / Pregnancy Idioma: En Revista: Fetal Diagn Ther Asunto de la revista: DIAGNOSTICO POR IMAGEM / OBSTETRICIA / PERINATOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Australia