Your browser doesn't support javascript.
loading
Convolutional neural networks for PET functional volume fully automatic segmentation: development and validation in a multi-center setting.
Iantsen, Andrei; Ferreira, Marta; Lucia, Francois; Jaouen, Vincent; Reinhold, Caroline; Bonaffini, Pietro; Alfieri, Joanne; Rovira, Ramon; Masson, Ingrid; Robin, Philippe; Mervoyer, Augustin; Rousseau, Caroline; Kridelka, Frédéric; Decuypere, Marjolein; Lovinfosse, Pierre; Pradier, Olivier; Hustinx, Roland; Schick, Ulrike; Visvikis, Dimitris; Hatt, Mathieu.
Afiliación
  • Iantsen A; LaTIM, INSERM, UMR 1101, University Brest, Brest, France. andrei.iantsen@inserm.fr.
  • Ferreira M; GIGA-CRC in vivo Imaging, University of Liège, Liège, Belgium.
  • Lucia F; LaTIM, INSERM, UMR 1101, University Brest, Brest, France.
  • Jaouen V; LaTIM, INSERM, UMR 1101, University Brest, Brest, France.
  • Reinhold C; Department of Radiology, McGill University Health Centre (MUHC), Montreal, Canada.
  • Bonaffini P; Department of Radiology, McGill University Health Centre (MUHC), Montreal, Canada.
  • Alfieri J; Department of Radiation Oncology, McGill University Health Centre (MUHC), Montreal, Canada.
  • Rovira R; Gynecology Oncology and Laparoscopy Department, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.
  • Masson I; Department of Radiation Oncology, Institut de Cancérologie de l'Ouest (ICO), Nantes, France.
  • Robin P; Nuclear Medicine Department, University Hospital, Brest, France.
  • Mervoyer A; Department of Radiation Oncology, Institut de Cancérologie de l'Ouest (ICO), Nantes, France.
  • Rousseau C; Nuclear Medicine Department, Institut de Cancérologie de l'Ouest (ICO), Nantes, France.
  • Kridelka F; Division of Oncological Gynecology, University Hospital of Liège, Liège, Belgium.
  • Decuypere M; Division of Oncological Gynecology, University Hospital of Liège, Liège, Belgium.
  • Lovinfosse P; Division of Nuclear Medicine and Oncological Imaging, University Hospital of Liège, Liège, Belgium.
  • Pradier O; LaTIM, INSERM, UMR 1101, University Brest, Brest, France.
  • Hustinx R; GIGA-CRC in vivo Imaging, University of Liège, Liège, Belgium.
  • Schick U; LaTIM, INSERM, UMR 1101, University Brest, Brest, France.
  • Visvikis D; LaTIM, INSERM, UMR 1101, University Brest, Brest, France.
  • Hatt M; LaTIM, INSERM, UMR 1101, University Brest, Brest, France.
Eur J Nucl Med Mol Imaging ; 48(11): 3444-3456, 2021 10.
Article en En | MEDLINE | ID: mdl-33772335
ABSTRACT

PURPOSE:

In this work, we addressed fully automatic determination of tumor functional uptake from positron emission tomography (PET) images without relying on other image modalities or additional prior constraints, in the context of multicenter images with heterogeneous characteristics.

METHODS:

In cervical cancer, an additional challenge is the location of the tumor uptake near or even stuck to the bladder. PET datasets of 232 patients from five institutions were exploited. To avoid unreliable manual delineations, the ground truth was generated with a semi-automated

approach:

a volume containing the tumor and excluding the bladder was first manually determined, then a well-validated, semi-automated approach relying on the Fuzzy locally Adaptive Bayesian (FLAB) algorithm was applied to generate the ground truth. Our model built on the U-Net architecture incorporates residual blocks with concurrent spatial squeeze and excitation modules, as well as learnable non-linear downsampling and upsampling blocks. Experiments relied on cross-validation (four institutions for training and validation, and the fifth for testing).

RESULTS:

The model achieved good Dice similarity coefficient (DSC) with little variability across institutions (0.80 ± 0.03), with higher recall (0.90 ± 0.05) than precision (0.75 ± 0.05) and improved results over the standard U-Net (DSC 0.77 ± 0.05, recall 0.87 ± 0.02, precision 0.74 ± 0.08). Both vastly outperformed a fixed threshold at 40% of SUVmax (DSC 0.33 ± 0.15, recall 0.52 ± 0.17, precision 0.30 ± 0.16). In all cases, the model could determine the tumor uptake without including the bladder. Neither shape priors nor anatomical information was required to achieve efficient training.

CONCLUSION:

The proposed method could facilitate the deployment of a fully automated radiomics pipeline in such a challenging multicenter context.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Redes Neurales de la Computación Tipo de estudio: Clinical_trials / Prognostic_studies Límite: Humans Idioma: En Revista: Eur J Nucl Med Mol Imaging Asunto de la revista: MEDICINA NUCLEAR Año: 2021 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Redes Neurales de la Computación Tipo de estudio: Clinical_trials / Prognostic_studies Límite: Humans Idioma: En Revista: Eur J Nucl Med Mol Imaging Asunto de la revista: MEDICINA NUCLEAR Año: 2021 Tipo del documento: Article País de afiliación: Francia