Your browser doesn't support javascript.
loading
Differential Response of Pentanal and Hexanal Exhalation to Supplemental Oxygen and Mechanical Ventilation in Rats.
Müller-Wirtz, Lukas M; Kiefer, Daniel; Knauf, Joschua; Floss, Maximilian A; Doneit, Jonas; Wolf, Beate; Maurer, Felix; Sessler, Daniel I; Volk, Thomas; Kreuer, Sascha; Fink, Tobias.
Afiliación
  • Müller-Wirtz LM; CBR-Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, 66421 Saarland, Germany.
  • Kiefer D; Outcomes Research Consortium, Cleveland, OH 44195, USA.
  • Knauf J; CBR-Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, 66421 Saarland, Germany.
  • Floss MA; CBR-Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, 66421 Saarland, Germany.
  • Doneit J; CBR-Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, 66421 Saarland, Germany.
  • Wolf B; CBR-Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, 66421 Saarland, Germany.
  • Maurer F; CBR-Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, 66421 Saarland, Germany.
  • Sessler DI; CBR-Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, 66421 Saarland, Germany.
  • Volk T; Outcomes Research Consortium, Cleveland, OH 44195, USA.
  • Kreuer S; Outcomes Research Consortium, Cleveland, OH 44195, USA.
  • Fink T; Department of Outcomes Research, Anesthesiology Institute, Cleveland Clinic, Cleveland, OH 44195, USA.
Molecules ; 26(9)2021 May 07.
Article en En | MEDLINE | ID: mdl-34067078
ABSTRACT
High inspired oxygen during mechanical ventilation may influence the exhalation of the previously proposed breath biomarkers pentanal and hexanal, and additionally induce systemic inflammation. We therefore investigated the effect of various concentrations of inspired oxygen on pentanal and hexanal exhalation and serum interleukin concentrations in 30 Sprague Dawley rats mechanically ventilated with 30, 60, or 93% inspired oxygen for 12 h. Pentanal exhalation did not differ as a function of inspired oxygen but increased by an average of 0.4 (95%CI 0.3; 0.5) ppb per hour, with concentrations doubling from 3.8 (IQR 2.8; 5.1) ppb at baseline to 7.3 (IQR 5.0; 10.8) ppb after 12 h. Hexanal exhalation was slightly higher at 93% of inspired oxygen with an average difference of 0.09 (95%CI 0.002; 0.172) ppb compared to 30%. Serum IL-6 did not differ by inspired oxygen, whereas IL-10 at 60% and 93% of inspired oxygen was greater than with 30%. Both interleukins increased over 12 h of mechanical ventilation at all oxygen concentrations. Mechanical ventilation at high inspired oxygen promotes pulmonary lipid peroxidation and systemic inflammation. However, the response of pentanal and hexanal exhalation varies, with pentanal increasing by mechanical ventilation, whereas hexanal increases by high inspired oxygen concentrations.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Oxígeno / Respiración Artificial / Espiración / Aldehídos Límite: Animals Idioma: En Revista: Molecules Asunto de la revista: BIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Oxígeno / Respiración Artificial / Espiración / Aldehídos Límite: Animals Idioma: En Revista: Molecules Asunto de la revista: BIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania