Your browser doesn't support javascript.
loading
isoSTED microscopy with water-immersion lenses and background reduction.
Siegmund, René; Werner, Frank; Jakobs, Stefan; Geisler, Claudia; Egner, Alexander.
Afiliación
  • Siegmund R; Department of Optical Nanoscopy, Institute for Nanophotonics Göttingen, Göttingen, Germany.
  • Werner F; Institute of Mathematics, University of Würzburg, Würzburg, Germany.
  • Jakobs S; Department of NanoBiophotonics, Max Planck Institute for Biophysical Chemistry, Göttingen, Germany; Cluster of Excellence "Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Göttingen, Germany.
  • Geisler C; Department of Optical Nanoscopy, Institute for Nanophotonics Göttingen, Göttingen, Germany.
  • Egner A; Department of Optical Nanoscopy, Institute for Nanophotonics Göttingen, Göttingen, Germany; Cluster of Excellence "Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Göttingen, Germany. Electronic address: alexander.egner@ifnano.de.
Biophys J ; 120(16): 3303-3314, 2021 08 17.
Article en En | MEDLINE | ID: mdl-34246627
Fluorescence microscopy is an excellent tool to gain knowledge on cellular structures and biochemical processes. Stimulated emission depletion (STED) microscopy provides a resolution in the range of a few 10 nm at relatively fast data acquisition. As cellular structures can be oriented in any direction, it is of great benefit if the microscope exhibits an isotropic resolution. Here, we present an isoSTED microscope that utilizes water-immersion objective lenses and enables imaging of cellular structures with an isotropic resolution of better than 60 nm in living samples at room temperature and without CO2 supply or another pH control. This corresponds to a reduction of the focal volume by far more than two orders of magnitude as compared to confocal microscopy. The imaging speed is in the range of 0.8 s/µm3. Because fluorescence signal can only be detected from a diffraction-limited volume, a background signal is inevitably observed at resolutions well beyond the diffraction limit. Therefore, we additionally present a method that allows us to identify this unspecific background signal and to remove it from the image.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Agua / Inmersión Idioma: En Revista: Biophys J Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Agua / Inmersión Idioma: En Revista: Biophys J Año: 2021 Tipo del documento: Article País de afiliación: Alemania