Your browser doesn't support javascript.
loading
Can the introduction of single-use flexible ureteroscopes increase the longevity of reusable flexible ureteroscopes at a high volume centre?
Ventimiglia, Eugenio; Smyth, Niamh; Doizi, Steeve; Jiménez Godínez, Alvaro; Barghouthy, Yazeed; Corrales Acosta, Mariela Alejandra; Kamkoum, Hatem; Somani, Bhaskar; Traxer, Olivier.
Afiliación
  • Ventimiglia E; GRC n°20, Groupe de Recherche Clinique sur la Lithiase Urinaire, Hôpital Tenon, Sorbonne Université, 75020, Paris, France.
  • Smyth N; Service d'Urologie, Assistance-Publique Hôpitaux de Paris, Hôpital Tenon, Sorbonne Université, 4 rue de la Chine, 75020, Paris, France.
  • Doizi S; Division of Experimental Oncology/Unit of Urology, URI-Urological Research Institute, IRCCS Ospedale San Raffaele, 20132, Milan, Italy.
  • Jiménez Godínez A; University Hospital Monklands, Monkscourt Avenue, Airdrie, ML60JS, UK.
  • Barghouthy Y; GRC n°20, Groupe de Recherche Clinique sur la Lithiase Urinaire, Hôpital Tenon, Sorbonne Université, 75020, Paris, France.
  • Corrales Acosta MA; Service d'Urologie, Assistance-Publique Hôpitaux de Paris, Hôpital Tenon, Sorbonne Université, 4 rue de la Chine, 75020, Paris, France.
  • Kamkoum H; Department of Surgery, University of Guadalajara, Guadalajara, Jalisco, Mexico.
  • Somani B; GRC n°20, Groupe de Recherche Clinique sur la Lithiase Urinaire, Hôpital Tenon, Sorbonne Université, 75020, Paris, France.
  • Traxer O; Service d'Urologie, Assistance-Publique Hôpitaux de Paris, Hôpital Tenon, Sorbonne Université, 4 rue de la Chine, 75020, Paris, France.
World J Urol ; 40(1): 251-256, 2022 Jan.
Article en En | MEDLINE | ID: mdl-34424373
OBJECTIVES: To assess whether the introduction of single use flexibles ureteroscopes (su-fURS) at our high-volume centre had an advantageous impact on the turn-over and breakage rates of reusable fURS (re-fURS). METHODS: We analysed re-fURS number of usages and breakages at our centre between February 2015 and December 2018. We recorded the number of usages for analysed scope between the first usage until a breakage requiring reconditioning. Usage count was restarted following each reconditioning episode. Since su-fURS (Lithovue, Boston Scientific, USA) were introduced at our center in September 2016, we had the chance to compare different re-fURS life cycles according to both su-fURS availability and usage intensity (i.e., number of su-fURS used during each re-fURS life cycle). We then explored the relationship between su-fURS usage intensity and reusable scope survival (i.e., number of utilizations before any breakage requiring reconditioning) using locally weighted scatterplot smoothing (LOWESS) approach. RESULTS: Five different re-fURSs were employed at our centre, for a total of 1820 usages and 40 breakages requiring reconditioning. The overall mean (SD) number of usages before breaking was 40 (22). After su-fURS introduction, mean (SD) re-fURS number of usages increased from 35 (22) to 49 (20), (+ 40%, p = 0.02). The relationship between su-fURS usage intensity and reusable scopes survival showed a linear survival increase after 10 or more su-fURS scopes were used per life cycle. CONCLUSIONS: The life cycle of re-fURS increased by 40% after the introduction of su-fURS. Ten or more used su-fURS per life cycle were associated with increased re-fURS survival.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Equipo Reutilizado / Ureteroscopios / Equipos Desechables Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: World J Urol Año: 2022 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Equipo Reutilizado / Ureteroscopios / Equipos Desechables Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: World J Urol Año: 2022 Tipo del documento: Article País de afiliación: Francia