Your browser doesn't support javascript.
loading
Fluorescent paper strip immunoassay with carbon nanodots@silica for determination of human serum amyloid A1.
Supianto, Mulya; Lee, Sang Hyuk; Jhung, Sung Hwa; Mohammad, Hazara Begum; Vu, Hung M; Kim, Min-Sik; Song, Woo-Young; Kim, Tae-Young; Lee, Hye Jin.
Afiliación
  • Supianto M; Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University, 80 Daehakro, Buk-gu, Daegu-city, 41566, Republic of Korea.
  • Lee SH; Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University, 80 Daehakro, Buk-gu, Daegu-city, 41566, Republic of Korea.
  • Jhung SH; Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University, 80 Daehakro, Buk-gu, Daegu-city, 41566, Republic of Korea.
  • Mohammad HB; Department of New Biology, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, 42988, Republic of Korea.
  • Vu HM; Department of New Biology, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, 42988, Republic of Korea.
  • Kim MS; Department of New Biology, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, 42988, Republic of Korea.
  • Song WY; School of Earth Sciences and Environmental Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, 61005, Republic of Korea.
  • Kim TY; School of Earth Sciences and Environmental Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, 61005, Republic of Korea.
  • Lee HJ; Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University, 80 Daehakro, Buk-gu, Daegu-city, 41566, Republic of Korea. hyejinlee@knu.ac.kr.
Mikrochim Acta ; 188(11): 386, 2021 10 18.
Article en En | MEDLINE | ID: mdl-34664145
A fluorescent paper strip immunoassay in conjunction with carbon nanodots@silica (CND@SiO2) as a label was developed for the quantitative measurements of human serum amyloid A1 (hSAA1) in serum at clinically significant concentrations for lung cancer diagnosis. Monodispersed CND@SiO2 was prepared by cohydrolysis between silane-crosslinked carbon nanodots and silica precursors via the Ströber method and further attached covalently to anti-hSAA1 (14F8) monoclonal antibody [anti-hSAA1(14F8)] specific to the hSAA1 target. The hSAA1 concentrations were then determined by quantifying the blue fluorescence intensity upon 365 nm excitation of the captured hSAA1 with anti-hSAA1(14F8)-CND@SiO2 conjugates in the test line on a paper strip where anti-hSAA1 (10G1) monoclonal antibody was physisorbed. The developed fluorescent paper strip with CND@SiO2 can detect hSAA1 at concentrations ranging from 0.1 to 5 nM (R2 = 0.995), with a limit of detection of  0.258 nM in 10 mM phosphate buffer pH 7.4 containing human serum albumin. The performance of  recovery (90.98-109.17%) and repeatability (coefficients of variation < 8.46%) obtained was also acceptable for quantitative determinations. The platform was employed for direct determination of hSAA1 concentrations in undiluted serum samples from lung cancer patients (relative standard deviation (RSD) < 7.46%) and healthy humans (RSD < 3.96%). The results were compared with those obtained using a commercially available enzyme-linked immunosorbent assay alongside liquid chromatography with tandem mass spectrometry measurements.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Proteína Amiloide A Sérica / Inmunoensayo / Carbono / Dióxido de Silicio Límite: Humans Idioma: En Revista: Mikrochim Acta Año: 2021 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Proteína Amiloide A Sérica / Inmunoensayo / Carbono / Dióxido de Silicio Límite: Humans Idioma: En Revista: Mikrochim Acta Año: 2021 Tipo del documento: Article