Your browser doesn't support javascript.
loading
On-Scalp Optically Pumped Magnetometers versus Cryogenic Magnetoencephalography for Diagnostic Evaluation of Epilepsy in School-aged Children.
Feys, Odile; Corvilain, Pierre; Aeby, Alec; Sculier, Claudine; Holmes, Niall; Brookes, Matthew; Goldman, Serge; Wens, Vincent; De Tiège, Xavier.
Afiliación
  • Feys O; From the Departments of Neurology (O.F.), Pediatric Neurology (C.S., F.C.), Nuclear Medicine (S.G.), and Translational Neuroimaging (V.W., X.D.T.), CUB Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Translational Neuroimaging and Neuroanatomy (Laboratoire de Neuroima
  • Corvilain P; From the Departments of Neurology (O.F.), Pediatric Neurology (C.S., F.C.), Nuclear Medicine (S.G.), and Translational Neuroimaging (V.W., X.D.T.), CUB Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Translational Neuroimaging and Neuroanatomy (Laboratoire de Neuroima
  • Aeby A; From the Departments of Neurology (O.F.), Pediatric Neurology (C.S., F.C.), Nuclear Medicine (S.G.), and Translational Neuroimaging (V.W., X.D.T.), CUB Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Translational Neuroimaging and Neuroanatomy (Laboratoire de Neuroima
  • Sculier C; From the Departments of Neurology (O.F.), Pediatric Neurology (C.S., F.C.), Nuclear Medicine (S.G.), and Translational Neuroimaging (V.W., X.D.T.), CUB Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Translational Neuroimaging and Neuroanatomy (Laboratoire de Neuroima
  • Holmes N; From the Departments of Neurology (O.F.), Pediatric Neurology (C.S., F.C.), Nuclear Medicine (S.G.), and Translational Neuroimaging (V.W., X.D.T.), CUB Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Translational Neuroimaging and Neuroanatomy (Laboratoire de Neuroima
  • Brookes M; From the Departments of Neurology (O.F.), Pediatric Neurology (C.S., F.C.), Nuclear Medicine (S.G.), and Translational Neuroimaging (V.W., X.D.T.), CUB Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Translational Neuroimaging and Neuroanatomy (Laboratoire de Neuroima
  • Goldman S; From the Departments of Neurology (O.F.), Pediatric Neurology (C.S., F.C.), Nuclear Medicine (S.G.), and Translational Neuroimaging (V.W., X.D.T.), CUB Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Translational Neuroimaging and Neuroanatomy (Laboratoire de Neuroima
  • Wens V; From the Departments of Neurology (O.F.), Pediatric Neurology (C.S., F.C.), Nuclear Medicine (S.G.), and Translational Neuroimaging (V.W., X.D.T.), CUB Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Translational Neuroimaging and Neuroanatomy (Laboratoire de Neuroima
  • De Tiège X; From the Departments of Neurology (O.F.), Pediatric Neurology (C.S., F.C.), Nuclear Medicine (S.G.), and Translational Neuroimaging (V.W., X.D.T.), CUB Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Translational Neuroimaging and Neuroanatomy (Laboratoire de Neuroima
Radiology ; 304(2): 429-434, 2022 08.
Article en En | MEDLINE | ID: mdl-35503013
ABSTRACT
Background Magnetoencephalography (MEG) is an established method used to detect and localize focal interictal epileptiform discharges (IEDs). Current MEG systems house hundreds of cryogenic sensors in a rigid, one-size-fits-all helmet, which results in several limitations, particularly in children. Purpose To determine if on-scalp MEG based on optically pumped magnetometers (OPMs) alleviates the main limitations of cryogenic MEG. Materials and Methods In this prospective single-center study conducted in a tertiary university teaching hospital, participants underwent cryogenic (102 magnetometers, 204 planar gradiometers) and on-scalp (32 OPMs) MEG. The two modalities for the detection and localization of IEDs were compared. The t test was used to compare IED amplitude and signal-to-noise ratio (SNR). Distributed source modeling was performed on OPM-based and cryogenic MEG data. Results Five children (median age, 9.4 years [range, 5-11 years]; four girls) with self-limited idiopathic (n = 3) or refractory (n = 2) focal epilepsy were included. IEDs were identified in all five children with comparable sensor topographies for both MEG devices. IED amplitudes were 2.3 (7.2 of 3.1) to 4.6 (3.2 of 0.7) times higher (P < .001) with on-scalp MEG, and the SNR was 27% (16.7 of 13.2) to 60% (12.8 of 8.0) higher (P value range .001-.009) with on-scalp MEG in all but one participant (P = .93), whose head movements created pronounced motion artifacts. The neural source of averaged IEDs was located at approximately 5 mm (n = 3) or higher (8.3 mm, n = 1; 15.6 mm, n = 1) between on-scalp and cryogenic MEG. Conclusion Despite the limited number of sensors and scalp coverage, on-scalp magnetoencephalography (MEG) based on optically pumped magnetometers helped detect interictal epileptiform discharges in school-aged children with epilepsy with a higher amplitude, higher signal-to-noise ratio, and similar localization value compared with conventional cryogenic MEG. Online supplemental material is available for this article. © RSNA, 2022 See also the editorial by Widjaja in this issue.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Epilepsias Parciales / Epilepsia Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Child / Female / Humans Idioma: En Revista: Radiology Año: 2022 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Epilepsias Parciales / Epilepsia Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Child / Female / Humans Idioma: En Revista: Radiology Año: 2022 Tipo del documento: Article