Your browser doesn't support javascript.
loading
Exercise capacity assessed with the one-minute sit-to-stand test (1-min STST) and echocardiographic findings in patients with heart failure with preserved ejection fraction (HFpEF).
Kronberger, Christina; Mousavi, Roya Anahita; Öztürk, Begüm; Dachs, Theresa-Marie; Rettl, René; Camuz-Ligios, Luciana; Litschauer, Brigitte; Badr-Eslam, Roza.
Afiliación
  • Kronberger C; Department of Internal Medicine II, Division of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria.
  • Mousavi RA; Department of Internal Medicine II, Division of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria.
  • Öztürk B; Department of Internal Medicine II, Division of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria.
  • Dachs TM; Department of Internal Medicine II, Division of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria.
  • Rettl R; Department of Internal Medicine II, Division of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria.
  • Camuz-Ligios L; Department of Internal Medicine II, Division of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria.
  • Litschauer B; Department of Clinical Pharmacology, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria.
  • Badr-Eslam R; Department of Internal Medicine II, Division of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria. Electronic address: roza.badreslam@meduniwien.ac.at.
Heart Lung ; 55: 134-139, 2022.
Article en En | MEDLINE | ID: mdl-35567840
ABSTRACT

BACKGROUND:

Heart failure with preserved ejection fraction (HFpEF) is a major cause of morbidity and mortality. Precise risk stratification remains challenging. The one-minute sit-to-stand-test (1-min STST), a quick, objective test of functional capacity may be helpful for stratification of clinical profile in HFpEF patients.

OBJECTIVE:

The aim of this initial investigation was to prospectively examine whether the 1-min STST can be used for the evaluation of exercise capacity in HFpEF patients and whether it is in line with echocardiographic as well as quality of life (QoL) findings.

METHODS:

39 HFpEF patients were prospectively studied. Functional performance was examined with the 1-min STST and QoL with the CAMPHOR questionnaire. Clinical parameters including echocardiographic measurements [estimated pulmonary artery systolic pressure (ePASP), tricuspid regurgitation velocity (TRV)] were obtained. Patients were divided into two groups based on their number of 1-min STST repetitions (Group I ≤50% of predicted 1-min STST repetitions using the norm-reference values developed by Strassmann et al. for healthy people, N=24; Group II >50% of predicted 1-min STST repetitions, N=15).

RESULTS:

Patients in group I with limited 1-min STST performance showed worse echocardiographic parameters [higher ePASP (p=0.038), higher TRV (p=0.018) and more reduced tricuspid annular plane systolic excursion (TAPSE) (p=0.001)], worse six-minute walk test (6MWT) (p<0.001) and worse QoL (p<0.001) compared to patients in group II.

CONCLUSION:

Our study shows potential usefulness of the 1-min STST as an evaluative tool for exercise capacity in HFpEF patients, because patients with worse 1-min STST performance have worse clinical parameters and QoL.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tolerancia al Ejercicio / Insuficiencia Cardíaca Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Heart Lung Año: 2022 Tipo del documento: Article País de afiliación: Austria

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tolerancia al Ejercicio / Insuficiencia Cardíaca Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Heart Lung Año: 2022 Tipo del documento: Article País de afiliación: Austria