Your browser doesn't support javascript.
loading
Intraocular Pressure Measurement in Childhood Glaucoma under Standardized General Anaesthesia: The Prospective EyeBIS Study.
Strzalkowska, Alicja; Pirlich, Nina; Stingl, Julia V; Schuster, Alexander K; Rezapour, Jasmin; Wagner, Felix M; Buse, Justus; Hoffmann, Esther M.
Afiliación
  • Strzalkowska A; Department of Ophthalmology, University Medical Centre of the Johannes Gutenberg, University Mainz, 55131 Mainz, Germany.
  • Pirlich N; Department of Anaesthesiology, University Medical Centre of the Johannes Gutenberg, University Mainz, 55131 Mainz, Germany.
  • Stingl JV; Department of Ophthalmology, University Medical Centre of the Johannes Gutenberg, University Mainz, 55131 Mainz, Germany.
  • Schuster AK; Department of Ophthalmology, University Medical Centre of the Johannes Gutenberg, University Mainz, 55131 Mainz, Germany.
  • Rezapour J; Department of Ophthalmology, University Medical Centre of the Johannes Gutenberg, University Mainz, 55131 Mainz, Germany.
  • Wagner FM; Department of Ophthalmology, University Medical Centre of the Johannes Gutenberg, University Mainz, 55131 Mainz, Germany.
  • Buse J; Department of Ophthalmology, University Medical Centre of the Johannes Gutenberg, University Mainz, 55131 Mainz, Germany.
  • Hoffmann EM; Department of Ophthalmology, University Medical Centre of the Johannes Gutenberg, University Mainz, 55131 Mainz, Germany.
J Clin Med ; 11(10)2022 May 18.
Article en En | MEDLINE | ID: mdl-35628971
Objective: We aimed to compare intraocular pressure (IOP) measurements using iCare® PRO rebound tonometry (iCare) and Perkins applanation tonometry (Perkins) in childhood glaucoma subjects and healthy children and the influence of anaesthesia depth, age and corneal thickness. Material: Prospective clinical, case-control study of children who underwent an ophthalmologic examination under general anaesthesia according to our protocol. Children were 45.45 ± 29.76 months old (mean ± SD (standard deviation)). Of all children, 54.05% were female. IOP was taken three times (T1−T3), according to duration and the depth of anaesthesia. The order of measurement alternated, starting with iCare. Agreement between the device measurements was evaluated using Bland−Altman analysis. Results: 53 glaucoma subjects and 22 healthy controls. Glaucoma subjects: IOP measured with iCare was at T1: 27.2 (18.1−33.8), T2: 21.6 (14.8−30.6), T3: 20.4 mmHg (14.5−27.0) and Perkins 17.5 (12.0−23.0), 15.5 (10.5−20.5), 15.0 mmHg (10.5−21.0) (median ± IQR (interquartile range)). Healthy controls: IOP with iCare: T1: 13.3 (11.1−17.0), T2: 10.6 (8.1−12.4), T3: 9.6 mmHg (7.7−11.7) and Perkins 10.3 (8.0−12.0), 7.0 (5.5−10.5), 7.0 mmHg (5.5−8.5) (median ± IQR). The median IOP was statistically significantly higher with iCare than with Perkins (p < 0.001) in both groups. The mean difference (iCare and Perkins) was 6.0 ± 6.1 mmHg for T1−T3, 7.3 at T1, 6.0 at T2, 4.9 mmHg at T3. Conclusion: The IOP was the highest in glaucoma subjects and healthy children at T1 (under sedation), independently of the measurement method. iCare always leads to higher IOP compared to Perkins in glaucoma and healthy subjects, regardless of the duration of anesthesia.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Guideline / Observational_studies Idioma: En Revista: J Clin Med Año: 2022 Tipo del documento: Article País de afiliación: Alemania