Your browser doesn't support javascript.
loading
BAlloon expandable vs. SElf expanding transcatheter vaLve for degenerated bioprosthesIs: design and rationale of the BASELINE trial.
Nuis, Rutger-Jan; van Belle, Eric; Teles, Rui; Blackman, Daniel; Veulemans, Verena; Santos, Ignacio Amat; Pilgrim, Thomas; Tarantini, Giuseppe; Saia, Francesco; Iakovou, Ioannis; Mascherbauer, Julia; Vincent, Flavien; Geleijnse, Marcel; Sathananthan, Janarthanan; Wood, David; Makkar, Raj; Van Mieghem, Nicolas M.
Afiliación
  • Nuis RJ; Department of Cardiology, Erasmus University Medical Center, Rotterdam, Netherlands.
  • van Belle E; Department of Cardiology, Institut Cœur Poumon, Lille, France.
  • Teles R; Hospital de Santa Cruz, CHLO; Nova Medical School, Lisbon, Portugal.
  • Blackman D; Department of Cardiology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kindom.
  • Veulemans V; Division of Cardiology, Heinrich Heine University Medical Center Dusseldorf, Dusseldorf, Germany.
  • Santos IA; Departamento de Cardiología, Hospital Clínico Universitario, Valladolid, Spain.
  • Pilgrim T; Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Tarantini G; Department of Cardiac, Thoracic, Vascular Science and Public Health, University of Padova, Padua, Italy.
  • Saia F; U.O. Cardiologia, Dipartimento Cardio-Toraco-Vascolare, Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
  • Iakovou I; Department of Cardiology, Onassis Cardiac Surgery Center, Athens, Greece.
  • Mascherbauer J; Department of Cardiology, University Hospital St. Polten, Sankt Pölten, Austria.
  • Vincent F; Department of Cardiology, Institut Cœur Poumon, Lille, France.
  • Geleijnse M; Department of Cardiology, Erasmus University Medical Center, Rotterdam, Netherlands.
  • Sathananthan J; Centre for Cardiovascular and Heart Valve Innovation, St. Paul's and Vancouver General Hospital, Vancouver, Canada.
  • Wood D; Centre for Cardiovascular and Heart Valve Innovation, St. Paul's and Vancouver General Hospital, Vancouver, Canada.
  • Makkar R; Department of Cardiology, Cedars-Sinai Medical Center, Los Angeles, CA.
  • Van Mieghem NM; Department of Cardiology, Erasmus University Medical Center, Rotterdam, Netherlands. Electronic address: n.vanmieghem@erasmusmc.nl.
Am Heart J ; 256: 139-147, 2023 02.
Article en En | MEDLINE | ID: mdl-36410441
ABSTRACT

BACKGROUND:

Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis.

METHODS:

The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies.

CONCLUSIONS:

The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Estenosis de la Válvula Aórtica / Bioprótesis / Prótesis Valvulares Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Clinical_trials Límite: Humans Idioma: En Revista: Am Heart J Año: 2023 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Estenosis de la Válvula Aórtica / Bioprótesis / Prótesis Valvulares Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Clinical_trials Límite: Humans Idioma: En Revista: Am Heart J Año: 2023 Tipo del documento: Article País de afiliación: Países Bajos