Your browser doesn't support javascript.
loading
A novel aptamer beacon for rapid screening of recombinant cells and in vivo monitoring of recombinant proteins.
Zheng, Wei-Wei; Yang, Li-Ting; Zhou, Hang; Zhang, Zhi-Yue; Wang, Xin-Yi; Wu, Jing-Yi; Lu, Xin-Chen; Chen, Jing; Duan, Cai-Wen; Chen, Kai-Ming.
Afiliación
  • Zheng WW; Key Laboratory of Pediatric Hematology and Oncology Ministry of Health and Pediatric Translational Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Yang LT; Fujian Branch of Shanghai Children's Medical Center Affiliated to Shanghai Jiaotong University School of Medicine, and Fujian Children's Hospital, Fuzhou, Fujian, China.
  • Zhou H; Key Laboratory of Pediatric Hematology and Oncology Ministry of Health and Pediatric Translational Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Zhang ZY; Key Laboratory of Pediatric Hematology and Oncology Ministry of Health and Pediatric Translational Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Wang XY; Key Laboratory of Pediatric Hematology and Oncology Ministry of Health and Pediatric Translational Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Wu JY; Key Laboratory of Pediatric Hematology and Oncology Ministry of Health and Pediatric Translational Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Lu XC; Key Laboratory of Pediatric Hematology and Oncology Ministry of Health and Pediatric Translational Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Chen J; Key Laboratory of Pediatric Hematology and Oncology Ministry of Health and Pediatric Translational Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Duan CW; Key Laboratory of Pediatric Hematology and Oncology Ministry of Health and Pediatric Translational Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China. chenjing@scmc.com.cn.
  • Chen KM; Key Laboratory of Pediatric Hematology and Oncology Ministry of Health and Pediatric Translational Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China. duancaiwen@scmc.com.cn.
Appl Microbiol Biotechnol ; 107(2-3): 553-567, 2023 Feb.
Article en En | MEDLINE | ID: mdl-36517545
ABSTRACT
Recombinant protein drugs, which are typically produced by mammalian host cells, have been approved for the treatment of a range of diseases. Accordingly, systems for selecting recombinant cell lines with efficient protein expression and for testing the content of recombinant proteins in vivo are crucial to the large-scale production and application of protein-based therapeutic drugs. In this study, we designed three aptamer beacons to detect His-tag, a common label of recombinant proteins. We found that all three beacons could specifically and quantitatively measure the His-tagged recombinant proteins with a short reaction time. Among these three beacons, the 6H5-MU beacon had the highest sensitivity for His polypeptides with a detection limit of 250 ng/mL and the shortest detection time within 1 min. Furthermore, we established a rapid and highly effective recombinant cell line construction system, which could obtain monoclonal cell lines with high yields of target proteins within 21 days, by combining 6H5-MU with pSB, a novel plasmid composed of a Sleeping Beauty transposase and a transposon. Finally, 6H5-MU also discriminately tested the serum concentration of His-tagged recombinant proteins in vivo, with consistent results compared to enzyme-linked immunosorbent assay (ELISA). We thus established a rapid and high-throughput method for generating recombinant cell lines and in vivo monitoring of recombinant protein levels, thereby providing a new platform for the development and preparation of recombinant protein drugs. KEY POINTS • The 6H5-MU aptamer beacon rapidly and accurately binds to His-tagged recombinant proteins. • A system for rapid and high-throughput generation of recombinant cell lines is established using 6H5-MU and pSB. • 6H5-MU allows in vivo monitoring of recombinant protein levels.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Oligonucleótidos / Mamíferos Tipo de estudio: Diagnostic_studies / Screening_studies Límite: Animals Idioma: En Revista: Appl Microbiol Biotechnol Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Oligonucleótidos / Mamíferos Tipo de estudio: Diagnostic_studies / Screening_studies Límite: Animals Idioma: En Revista: Appl Microbiol Biotechnol Año: 2023 Tipo del documento: Article País de afiliación: China