Your browser doesn't support javascript.
loading
Mortality analysis of endovascular aneurysm sealing versus endovascular aneurysm repair.
Rastogi, Vinamr; O'Donnell, Thomas F X; Solomon, Yoel; Varkevisser, Rens R B; Patel, Priya B; Carpenter, Jeffrey P; de Bruin, Jorg L; Reijnen, Michel M P J; Verhagen, Hence J M; Schermerhorn, Marc L.
Afiliación
  • Rastogi V; Division of Vascular and Endovascular Surgery, Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA; Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, The Netherlands.
  • O'Donnell TFX; Division of Vascular and Endovascular Surgery, Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA.
  • Solomon Y; Division of Vascular and Endovascular Surgery, Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA; Department of Vascular Surgery, University Medical Center, Utrecht, The Netherlands.
  • Varkevisser RRB; Division of Vascular and Endovascular Surgery, Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA; Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, The Netherlands.
  • Patel PB; Division of Vascular and Endovascular Surgery, Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA.
  • Carpenter JP; Division of Vascular Surgery, Cooper Medical School of Rowan University, Camden, NJ.
  • de Bruin JL; Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, The Netherlands.
  • Reijnen MMPJ; Department of Surgery, Rijnstate, Arnhem, The Netherlands; Multi-Modality Medical Imaging Group, University of Twente, Enschede, The Netherlands.
  • Verhagen HJM; Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, The Netherlands.
  • Schermerhorn ML; Division of Vascular and Endovascular Surgery, Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA. Electronic address: mscherm@bidmc.harvard.edu.
J Vasc Surg ; 77(3): 731-740.e1, 2023 03.
Article en En | MEDLINE | ID: mdl-36651654
ABSTRACT

BACKGROUND:

Endovascular aneurysm sealing (EVAS), using the Nellix endovascular aneurysm sealing system, has been associated with high reintervention and migration rates. However, prior reports have suggested that EVAS might be related to a lower all-cause mortality compared with endovascular aneurysm repair (EVAR). In the present study, we examined the 5-year all-cause mortality trends after EVAS and EVAR.

METHODS:

We compared the 333 EVAS patients in the EVAS-1 Nellix U.S. investigational device exemption trial with 16,497 infrarenal EVAR controls from the Vascular Quality Initiative, treated between 2014 and 2016, after applying the exclusion criteria from the investigational device exemption trial (ie, hemodialysis, creatinine >2.0 mg/dL, rupture). As a secondary analysis, we stratified the patients by aneurysm diameter (<5.5 cm and ≥5.5 cm). We calculated propensity scores after adjusting for demographics, comorbidities, and anatomic characteristics and applied inverse probability weighting to compare the risk-adjusted long-term mortality using Kaplan-Meier and Cox regression analyses.

RESULTS:

After weighting, the EVAS group had experienced similar 5-year mortality compared with the controls from the Vascular Quality Initiative (EVAS vs EVAR, 18% vs 14%; hazard ratio [HR], 1.1; 95% confidence interval [CI], 0.71-1.7; P = .70). The subgroup analysis demonstrated that for patients with an aneurysm diameter of <5.5 cm, EVAS was associated with higher 5-year mortality compared with EVAR (19% vs 11%; HR, 2.4; 95% CI, 1.7-4.7; P = .013). In patients with an aneurysm diameter of ≥5.5 cm, EVAS was associated with lower mortality within the first 2 years (2-year mortality HR, 0.29; 95% CI, 0.13-0.62; P = .002). However, compared with EVAR, EVAS was associated with higher mortality between 2 and 5 years (HR, 1.9; 95% CI, 1.2-3.0; P = .005), with no mortality difference at 5 years (18% vs 17%; HR, 0.82; 95% CI, 0.4-1.4; P = .46).

CONCLUSIONS:

Within the overall population, EVAS was associated with similar 5-year mortality compared with EVAR. EVAS was associated with higher mortality for those with small aneurysms (<5.5 cm). For those with larger aneurysms (≥5.5 cm), EVAS was initially associated with lower mortality within the first 2 years, although this advantage was lost thereafter, with higher mortality after 2 years. Future studies are required to evaluate the specific causes of death and to elucidate the potential beneficial mechanism behind sac obliteration that leads to this potential initial survival benefit. This could help guide the development of future grafts with better proximal fixation and sealing that also incorporate sac obliteration.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Aneurisma de la Aorta Abdominal / Implantación de Prótesis Vascular / Procedimientos Endovasculares Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Vasc Surg Asunto de la revista: ANGIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Aneurisma de la Aorta Abdominal / Implantación de Prótesis Vascular / Procedimientos Endovasculares Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Vasc Surg Asunto de la revista: ANGIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Países Bajos