Your browser doesn't support javascript.
loading
Swept-Source OCT Mid-Peripheral Retinal Irregularity in Retinal Detachment and Posterior Vitreous Detachment Eyes.
Lake, Stewart R; Bottema, Murk J; Lange, Tyra; Williams, Keryn A; Reynolds, Karen J.
Afiliación
  • Lake SR; Flinders Institute for Health and Medical Research, GPO Box 2100, Adelaide 5001, Australia.
  • Bottema MJ; Medical Device Research Institute, College of Science and Engineering, Flinders University, GPO Box 2100, Adelaide 5001, Australia.
  • Lange T; Medical Device Research Institute, College of Science and Engineering, Flinders University, GPO Box 2100, Adelaide 5001, Australia.
  • Williams KA; Medical Device Research Institute, College of Science and Engineering, Flinders University, GPO Box 2100, Adelaide 5001, Australia.
  • Reynolds KJ; Flinders Institute for Health and Medical Research, GPO Box 2100, Adelaide 5001, Australia.
Bioengineering (Basel) ; 10(3)2023 Mar 19.
Article en En | MEDLINE | ID: mdl-36978768
ABSTRACT
Irregularities in retinal shape have been shown to correlate with axial length, a major risk factor for retinal detachment. To further investigate this association, a comparison was performed of the swept-source optical coherence tomography (SS OCT) peripheral retinal shape of eyes that had either a posterior vitreous detachment (PVD) or vitrectomy for retinal detachment. The objective was to identify a biomarker that can be tested as a predictor for retinal detachment. Eyes with a PVD (N = 88), treated retinal detachment (N = 67), or retinal tear (N = 53) were recruited between July 2020 and January 2022 from hospital retinal clinics in South Australia. The mid-peripheral retina was imaged in four quadrants with SS OCT. The features explored were patient age, eye axial length, and retinal shape irregularity quantified in the frequency domain. A discriminant analysis classifier to identify retinal detachment eyes was trained with two-thirds and tested with one-third of the sample. Retinal detachment eyes had greater irregularity than PVD eyes. A classifier trained using shape features from the superior and temporal retina had a specificity of 84% and a sensitivity of 48%. Models incorporating axial length were less successful, suggesting peripheral retinal irregularity is a better biomarker for retinal detachment than axial length. Mid-peripheral retinal irregularity can identify eyes that have experienced a retinal detachment.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Prognostic_studies / Risk_factors_studies Idioma: En Revista: Bioengineering (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Prognostic_studies / Risk_factors_studies Idioma: En Revista: Bioengineering (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Australia