Your browser doesn't support javascript.
loading
Entering into 2.0 cystinuric management with a medical digital tool to monitor urine pH: a prospective, randomized study.
Angerri, O; Gracia, S; Rousaud, F; Kanashiro, A; Emiliani, E.
Afiliación
  • Angerri O; Department of Urology, Fundació Puigvert, Universitat Autònoma de Barcelona, Barcelona, Spain. Electronic address: 33802oaf@comb.cat.
  • Gracia S; Department of Laboratory and Biochemistry, Fundació Puigvert, Universitat Autònoma de Barcelona, Spain.
  • Rousaud F; Department of Urology, Fundació Puigvert, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Kanashiro A; Department of Urology, Fundació Puigvert, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Emiliani E; Department of Urology, Fundació Puigvert, Universitat Autònoma de Barcelona, Barcelona, Spain.
Actas Urol Esp (Engl Ed) ; 47(9): 560-565, 2023 11.
Article en En, Es | MEDLINE | ID: mdl-37086842
BACKGROUND AND OBJECTIVES: Individuals with cystinuria can experiment recurrent lithiasis events due to the relative insolubility of cystine at physiological urine pH, resulting in renal function decline. The Lit-Control® pH Meter is a medical device that accurately allows urine pH self-monitoring. The main objective of this study was to compare the usability of the Lit-Control® pH Meter with the reactive strips for self-monitoring of urinary pH at home by patients with cystinuria, and their overall satisfaction with each tool. PATIENTS AND METHODS: We included 28 patients (9 females and 19 males, age 19-76 years), who were randomly assigned to monitor their urine pH with reactive strips (n = 17) or the Lit-Control® pH-meter (n = 11). RESULTS: After six months of use, the satisfaction with the two methods was similarly high, but the patients rated (0-10 scale) the pH meter better in terms of ease of learning (mean ±â€¯SD, 8.11 ±â€¯0.60 vs. 7.06 ±â€¯1.18; P = 0.038), ease to prepare (8.22 ±â€¯0.67 vs. 7.25 ±â€¯1.18; P = 0.034), and ease of use (8.22 ±â€¯0.67 vs. 7.25 ±â€¯1.39; P = 0.062). Overall, patients did not reach the alkalinization goals (pH between 7.0 and 8.0). CONCLUSIONS: The Lit-Control® pH Meter demonstrated to be an easy-to-use device that can facilitate urinary pH control by cystinuric patients. A prospective study is warranted to assess the correlation between urine pH monitoring, a treat to target approach, and the recurrence of cystine stones.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Cistinuria Tipo de estudio: Clinical_trials / Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En / Es Revista: Actas Urol Esp (Engl Ed) Año: 2023 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Cistinuria Tipo de estudio: Clinical_trials / Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En / Es Revista: Actas Urol Esp (Engl Ed) Año: 2023 Tipo del documento: Article