Your browser doesn't support javascript.
loading
A review and evaluation of orthodontic brackets, molar bands and orthodontic auxiliaries during orthognathic surgery: A prospective cohort study.
van Ommeren, Romee Me; van Riet, Tom Ct; Ho, Jean-Pierre Tf; Jonkman, Ronald Eg; Becking, Alfred G.
Afiliación
  • van Ommeren RM; Department of Orthodontics, ACTA Amsterdam, Amsterdam, the Netherlands.
  • van Riet TC; Department of Oral and Maxillofacial Surgery, Amsterdam UMC location AMC, Amsterdam, the Netherlands.
  • Ho JT; Department of Orthodontics, ACTA Amsterdam, Amsterdam, the Netherlands.
  • Jonkman RE; Department of Orthodontics, ACTA Amsterdam, Amsterdam, the Netherlands.
  • Becking AG; Department of Oral and Maxillofacial Surgery, Amsterdam UMC location AMC, Amsterdam, the Netherlands.
J Orthod ; 51(1): 79-86, 2024 Mar.
Article en En | MEDLINE | ID: mdl-37462079
OBJECTIVE: The primary aim of this study was to provide a review of the types and frequency of orthodontic brackets, molar bands and orthodontic auxiliaries used for patients undergoing orthognathic surgery. The secondary aim was to evaluate the risk of failure of these items during orthognathic surgery. METHODS: From three Dutch hospitals, 124 adult patients were included in this prospective cohort study. Five independent researchers collected the data during surgery using a specifically created data extraction form. The type of surgery, surgeon, orthodontist and type of orthodontic bracket, molar band or auxiliary were noted for each tooth. To evaluate their failure risk, the following variables were noted: failure and site; and type and cause of failure. RESULTS: Stainless-steel brackets were the most frequently (75.8%) used bracket type seen in patients undergoing orthognathic surgery. Ceramic brackets were seen in 24.2% of the cases and were only applied in the anterior region. Molar bands were present in 58.9% of the patients and mostly with bands on the first molars in combination with bonded tubes on the second molars. In 32.2% of all cases, one or more failures were noted. One-third of all failures were described as detachment of the molar tube on the most posterior molar. Kobayashi ligatures and powerpins showed the highest risk of failure (odds ratio [OR] 3.70, 95% confidence interval [CI] = 1.91-7.15). No significant difference in failure rate was found between stainless-steel brackets, molar bands (OR 0.34, 95% CI = 0.08-1.43) and ceramic brackets (OR 0.44, 95% CI = 0.14-1.45). CONCLUSION: Stainless-steel brackets, ceramic brackets, molar bands and surgical hooks are suitable for orthognathic cases. Kobayashi ligatures and powerpins had a significantly higher risk of failure so are not recommended for temporary intraoperative maxillomandibular fixation (TIO-MMF).
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Soportes Ortodóncicos / Cirugía Ortognática Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Adult / Humans Idioma: En Revista: J Orthod Asunto de la revista: ODONTOLOGIA / ORTODONTIA Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Soportes Ortodóncicos / Cirugía Ortognática Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Adult / Humans Idioma: En Revista: J Orthod Asunto de la revista: ODONTOLOGIA / ORTODONTIA Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos