Your browser doesn't support javascript.
loading
Coverage stability of peri-implant soft tissue dehiscence: A systematic review and meta-analysis.
Amid, Reza; Moscowchi, Anahita; Azizi, Soroush; Hosseini, Matineh; Hartoonian, Serlie.
Afiliación
  • Amid R; Research Institute for Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Moscowchi A; Department of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Azizi S; Research Institute for Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Hosseini M; Department of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Hartoonian S; Research Institute for Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
J Esthet Restor Dent ; 36(2): 284-294, 2024 Feb.
Article en En | MEDLINE | ID: mdl-37494605
ABSTRACT

OBJECTIVE:

The occurrence of peri-implant soft tissue dehiscence, especially in the esthetic zone, can be challenging. This study sought to investigate how the passage of time affects the outcomes of treatment for peri-implant soft tissue dehiscence coverage. MATERIALS AND

METHODS:

A literature search was performed up to April 2023 via PubMed, Scopus, and Web of Science to retrieve studies reporting the data on peri-implant soft tissue dehiscence of at least 2-time points (baseline and follow-up). Clinical trials with a minimum of 5 participants, reporting at least 1 primary outcome, and with a minimum follow-up of 3 months were included. The primary outcomes were the changes in dehiscence depth, complete coverage, and mean coverage at different time points.

RESULTS:

Seven studies with 112 participants and 119 implants were included. Dehiscence depth increased insignificantly between 3 to 6 months. Although the dehiscence depth increased from 6 to 12 months in the tunnel group, it decreased in the coronally advanced group, and a slight decrease was observed from 12 to 72 months. Soft tissue thickness was the predictor for soft tissue margin stability. However, no significant relationship was found between the baseline dehiscence depth and complete coverage.

CONCLUSIONS:

Within the limitations of this study, it seems prudent to wait at least 6 months to achieve a stable soft tissue margin. CLINICAL

SIGNIFICANCE:

The occurrence of peri-implant soft tissue dehiscence, especially in the esthetic zone, can be a challenging complication. It is important not only to achieve coverage but also to ensure that the treatment results remain stable in the long term, in order to satisfy both patients and clinicians. A reasonable approach would be to wait for at least 6 months to achieve a stable soft tissue margin.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Implantes Dentales / Implantación Dental Tipo de estudio: Prognostic_studies / Systematic_reviews Límite: Humans Idioma: En Revista: J Esthet Restor Dent Asunto de la revista: ODONTOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Irán

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Implantes Dentales / Implantación Dental Tipo de estudio: Prognostic_studies / Systematic_reviews Límite: Humans Idioma: En Revista: J Esthet Restor Dent Asunto de la revista: ODONTOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Irán