Your browser doesn't support javascript.
loading
In Vivo Dynamic and Static Analysis of Lymphatic Dysfunction in Lymphedema Using Near-Infrared Fluorescence Indocyanine Green Lymphangiography.
Cheon, Hwayeong; Lee, Sang-Hun; Kim, Sang Ah; Kim, Bumchul; Suh, Hyunsuk Peter; Jeon, Jae Yong.
Afiliación
  • Cheon H; Biomedical Engineering Research Center, Asan Medical Center, Seoul, Republic of Korea (H.C.).
  • Lee SH; Department of Optical Engineering, Kumoh National Institute of Technology, Gyeongbuk, Republic of Korea (S.-H.L.).
  • Kim SA; Department of Rehabilitation Medicine (S.A.K., B.K., J.Y.J.), Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Kim B; Department of Rehabilitation Medicine (S.A.K., B.K., J.Y.J.), Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Suh HP; Department of Plastic Surgery (H.P.S.), Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Jeon JY; Department of Rehabilitation Medicine (S.A.K., B.K., J.Y.J.), Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Arterioscler Thromb Vasc Biol ; 43(10): 2008-2022, 2023 10.
Article en En | MEDLINE | ID: mdl-37615112
ABSTRACT

BACKGROUND:

Near-infrared fluorescence indocyanine green lymphangiography, a primary modality for detecting lymphedema, which is a disease due to lymphatic obstruction, enables real-time observations of lymphatics and reveals not only the spatial distribution of drainage (static analysis) but also information on the lymphatic contraction (dynamic analysis).

METHODS:

We have produced total lymphatic obstruction in the upper limbs of 18 Sprague-Dawley rats through the dissection of proximal (brachial and axillary) lymph nodes and 20-Gy radiation (dissection limbs). After the model formation for 1 week, 9 animal models were observed for 6 weeks using near-infrared fluorescence indocyanine green lymphangiography by injecting 6-µL ICG-BSA (indocyanine green-bovine serum albumin) solution of 20-µg/mL concentration. The drainage pattern and leakage of lymph fluid were evaluated and time-domain signals of lymphatic contraction were observed in the distal lymphatic vessels. The obtained signals were converted to frequency-domain spectrums using signal processing.

RESULTS:

The results of both static and dynamic analyses proved to be effective in accurately identifying the extent of lymphatic disruption in the dissection limbs. The static analysis showed abnormal drainage patterns and increased leakage of lymph fluid to the periphery of the vessels compared with the control (normal) limbs. Meanwhile, the waveforms were changed and the contractile signal frequency increased by 58% in the dynamic analysis. Specifically, our findings revealed that regular lymphatic contractions, observed at a frequency range of 0.08 to 0.13 Hz in the control limbs, were absent in the dissection limbs. The contractile regularity was not fully restored for the follow-up period, indicating a persistent lymphatic obstruction.

CONCLUSIONS:

The dynamic analysis could detect the abnormalities of lymphatic circulation by observing the characteristics of signals, and it provided additional evaluation indicators that cannot be provided by the static analysis. Our findings may be useful for the early detection of the circulation problem as a functional evaluation indicator of the lymphatic system.