Uncertainty in magnetic resonance imaging-based prostate postimplant dosimetry: Results of a 10-person human observer study, and comparisons with automatic postimplant dosimetry.
Sanders, Jeremiah W; Tang, Chad; Kudchadker, Rajat J; Venkatesan, Aradhana M; Mok, Henry; Hanania, Alexander N; Thames, Howard D; Bruno, Teresa L; Starks, Christine; Santiago, Edwin; Cunningham, Mandy; Frank, Steven J.
Afiliación
  • Sanders JW; Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX. Electronic address: sanders.jeremiah@mayo.edu.
  • Tang C; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Kudchadker RJ; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Venkatesan AM; Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Mok H; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Hanania AN; Department of Radiation Oncology, Baylor College of Medicine, Houston TX.
  • Thames HD; Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Bruno TL; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Starks C; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Santiago E; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Cunningham M; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Frank SJ; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX.
Brachytherapy ; 22(6): 822-832, 2023.
Article en En | MEDLINE | ID: mdl-37716820
ABSTRACT

PURPOSE:

Uncertainties in postimplant quality assessment (QA) for low-dose-rate prostate brachytherapy (LDRPBT) are introduced at two

steps:

seed localization and contouring. We quantified how interobserver variability (IoV) introduced in both steps impacts dose-volume-histogram (DVH) parameters for MRI-based LDRPBT, and compared it with automatically derived DVH parameters. METHODS AND MATERIALS Twenty-five patients received MRI-based LDRPBT. Seven clinical observers contoured the prostate and four organs at risk, and 4 dosimetrists performed seed localization, on each MRI. Twenty-eight unique manual postimplant QAs were created for each patient from unique observer pairs. Reference QA and automatic QA were also performed for each patient. IoV of prostate, rectum, and external urinary sphincter (EUS) DVH parameters owing to seed localization and contouring was quantified with coefficients of variation. Automatically derived DVH parameters were compared with those of the reference plans.

RESULTS:

Coefficients of variation (CoVs) owing to contouring variability (CoVcontours) were significantly higher than those due to seed localization variability (CoVseeds) (median CoVcontours vs. median CoVseeds prostate D90-15.12% vs. 0.65%, p < 0.001; prostate V100-5.36% vs. 0.37%, p < 0.001; rectum V100-79.23% vs. 8.69%, p < 0.001; EUS V200-107.74% vs. 21.18%, p < 0.001). CoVcontours were lower when the contouring observers were restricted to the 3 radiation oncologists, but were still markedly higher than CoVseeds. Median differences in prostate D90, prostate V100, rectum V100, and EUS V200 between automatically computed and reference dosimetry parameters were 3.16%, 1.63%, -0.00 mL, and -0.00 mL, respectively.

CONCLUSIONS:

Seed localization introduces substantially less variability in postimplant QA than does contouring for MRI-based LDRPBT. While automatic seed localization may potentially help improve workflow efficiency, it has limited potential for improving the consistency and quality of postimplant dosimetry.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Braquiterapia Tipo de estudio: Guideline Límite: Humans / Male Idioma: En Revista: Brachytherapy Asunto de la revista: RADIOTERAPIA Año: 2023 Tipo del documento: Article