Your browser doesn't support javascript.
loading
Rapid detection of Salmonella enterica in primary production samples by eliminating DNA amplification inhibitors using an improved sample pre-treatment method.
Vinayaka, Aaydha Chidambara; Quyen, Than Linh; Huynh, Van Ngoc; Madsen, Mogens; Bang, Dang Duong; Wolff, Anders.
Afiliación
  • Vinayaka AC; Laboratory of Applied Micro and Nanotechnology (LAMINATE), DTU-Bioengineering (Department of Biotechnology and Biomedicine), Technical University of Denmark, Kgs. Lyngby, Denmark.
  • Quyen TL; Biolabchip group, DTU-Bioengineering (Department of Biotechnology and Biomedicine), Technical University of Denmark, Kgs. Lyngby, Denmark.
  • Huynh VN; Biolabchip group, DTU-Bioengineering (Department of Biotechnology and Biomedicine), Technical University of Denmark, Kgs. Lyngby, Denmark.
  • Madsen M; Biolabchip group, DTU-Bioengineering (Department of Biotechnology and Biomedicine), Technical University of Denmark, Kgs. Lyngby, Denmark.
  • Bang DD; Laboratory of Applied Micro and Nanotechnology (LAMINATE), DTU-Bioengineering (Department of Biotechnology and Biomedicine), Technical University of Denmark, Kgs. Lyngby, Denmark.
  • Wolff A; Biolabchip group, DTU-Bioengineering (Department of Biotechnology and Biomedicine), Technical University of Denmark, Kgs. Lyngby, Denmark.
Microb Biotechnol ; 16(11): 2105-2113, 2023 11.
Article en En | MEDLINE | ID: mdl-37776205
ABSTRACT
Sensitive detection of pathogens in livestock farms is an integral part of the One Health Action Plan of the European Union (EU). Ensuring this requires on-site testing devices that are compatible with complex matrices such as primary production samples. Among all, faeces are considered the most challenging matrix type that makes it difficult to identify pathogens because of complexity in sample preparation for molecular testing. We have developed a loop-mediated isothermal amplification (LAMP) based veterinary point-of-care (POC) device (VETPOD) and adapted it to detect Salmonella enterica in primary production samples. Three different sampling methods (semi-wet chicken faeces, boot socks collection and dust samples from poultry shed) were iteratively tested to assess their nature of complexity and possibility for adapting them as suitable sampling methods for on-site testing. During the study, the sample preparation method that included a two-step centrifugation combined with washing of the enriched Salmonella cells was found crucial in eliminating amplification inhibitors originating from the faecal matrices. A total of 90 samples were tested that included 60 samples for sensitivity study and 30 samples for relative level of detection (RLOD, a level of detection in comparison to ISO 65791 reference method). Overall, the VETPOD had a sensitivity of 90%, 84.62% and 81.82% for boot sock, faecal and dust samples, respectively. The RLOD was 2.23 CFU/25 g which was found to be 1.33 times higher than the ISO 65791. Performing with an excellent agreement with ISO 65791, the VETPOD proved as a promising alternative to detect Salmonella spp. in primary production and animal husbandry samples.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Salmonella enterica Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: Microb Biotechnol Año: 2023 Tipo del documento: Article País de afiliación: Dinamarca

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Salmonella enterica Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: Microb Biotechnol Año: 2023 Tipo del documento: Article País de afiliación: Dinamarca