Your browser doesn't support javascript.
loading
Ultrasound and surfactant-assisted dispersive liquid-liquid microextraction prior to poly(ethylene oxide)-mediated stacking in CE for highly sensitive determination of barbiturates in human fluids.
Tseng, Li Hsin; Liang, Pei-Chi; Chiu, Tai-Chia; Hsieh, Ming-Mu.
Afiliación
  • Tseng LH; Department of Chemistry, National Kaohsiung Normal University, Kaohsiung, Taiwan.
  • Liang PC; Department of Chemistry, National Kaohsiung Normal University, Kaohsiung, Taiwan.
  • Chiu TC; Department of Applied Science, National Taitung University, Taitung, Taiwan.
  • Hsieh MM; Department of Chemistry, National Kaohsiung Normal University, Kaohsiung, Taiwan.
J Sep Sci ; 46(23): e2300557, 2023 Dec.
Article en En | MEDLINE | ID: mdl-37803927
This study developed a facile, highly sensitive technique for extracting and quantifying barbiturates in serum samples. This method combined ultrasound and surfactant-assisted dispersive liquid-liquid microextraction with poly(ethylene oxide)-mediated stacking in capillary electrophoresis. Factors influencing the extraction and stacking performance, such as the type and volume of extraction solvents, the type and concentration of surfactant, extraction time, salt additives, sample matrix, solution pH, and composition of the background electrolyte, were carefully studied and optimized to achieve the optimal detection sensitivity. Under the optimized extraction (injecting 140 µL C2 H4 Cl2 into 1 mL of sample with pH 4 (5 mM sodium phosphate containing 0.05 mM Tween 20 and sonication for 1 min) and separation conditions (150 mM tris(hydroxymethyl)aminomethane-borate with pH 8.5 containing 0.5% (m/v) poly(ethylene oxide)), the limits of detection (signal-to-noise ratio = 3) of five barbiturates ranged from 0.20 to 0.33 ng/mL, and the calculated sensitivity improvement ranged from 868- to 1700-fold. The experimental results revealed excellent linearity (R2  > 0.99), with relative standard deviations of 2.1%-3.4% for the migration time and 4.3%-5.7% for the peak area. The recoveries of the spiked serum samples were 97.1% -110.3%. Our proposed approach offers a rapid and practical method for quantifying barbiturates in biological fluids.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tensoactivos / Microextracción en Fase Líquida Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Sep Sci Año: 2023 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tensoactivos / Microextracción en Fase Líquida Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Sep Sci Año: 2023 Tipo del documento: Article País de afiliación: Taiwán