Your browser doesn't support javascript.
loading
The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes.
Murata, Masaaki; Nakata, Hironobu; Iijima, Kengo; Adachi, Shunsuke; Seino, Yudai; Kiuchi, Kenji; Matsuda, Frederick; Randall, Michael J; Arnold, Kam; Galitzki, Nicholas; Johnson, Bradley R; Keating, Brian; Kusaka, Akito; Lloyd, John B; Seibert, Joseph; Silva-Feaver, Maximiliano; Tajima, Osamu; Terasaki, Tomoki; Yamada, Kyohei.
Afiliación
  • Murata M; Department of Physics, The University of Tokyo, Tokyo 113-0033, Japan.
  • Nakata H; Department of Physics, Kyoto University, Kitashirakawa Oiwake-cho, Sakyo-ku, Kyoto 606-8502, Japan.
  • Iijima K; Department of Physics, The University of Tokyo, Tokyo 113-0033, Japan.
  • Adachi S; Department of Physics, Kyoto University, Kitashirakawa Oiwake-cho, Sakyo-ku, Kyoto 606-8502, Japan.
  • Seino Y; Hakubi Center for Advanced Research, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-850, Japan.
  • Kiuchi K; Department of Physics, Kyoto University, Kitashirakawa Oiwake-cho, Sakyo-ku, Kyoto 606-8502, Japan.
  • Matsuda F; Joseph Henry Laboratories of Physics, Jadwin Hall, Princeton University, Princeton, New Jersey 08544, USA.
  • Randall MJ; Department of Physics, The University of Tokyo, Tokyo 113-0033, Japan.
  • Arnold K; Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency (JAXA), Sagamihara, Kanagawa 252-5210, Japan.
  • Galitzki N; Department of Physics, University of California, San Diego, La Jolla, California 92093, USA.
  • Johnson BR; Center for Astrophysics and Space Sciences, 9500 Gilman Dr., La Jolla, California 92093, USA.
  • Keating B; Department of Physics, University of California, San Diego, La Jolla, California 92093, USA.
  • Kusaka A; Center for Astrophysics and Space Sciences, 9500 Gilman Dr., La Jolla, California 92093, USA.
  • Lloyd JB; Department of Physics, University of Texas at Austin, Austin, Texas 78712, USA.
  • Seibert J; Weinberg Institute for Theoretical Physics, Texas Center for Cosmology and Astroparticle Physics, Austin, Texas 78712, USA.
  • Silva-Feaver M; Department of Astronomy, University of Virginia, Charlottesville, Virginia 22904, USA.
  • Tajima O; Department of Physics, University of California, San Diego, La Jolla, California 92093, USA.
  • Terasaki T; Center for Astrophysics and Space Sciences, 9500 Gilman Dr., La Jolla, California 92093, USA.
  • Yamada K; Department of Physics, The University of Tokyo, Tokyo 113-0033, Japan.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Article en En | MEDLINE | ID: mdl-38109472
ABSTRACT
For cosmic microwave background (CMB) polarization observations, calibration of detector polarization angles is essential. We have developed a fully remote controlled calibration system with a sparse wire grid that reflects linearly polarized light along the wire direction. The new feature is a remote-controlled system for regular calibration, which has not been possible in sparse wire grid calibrators in past experiments. The remote control can be achieved by two electric linear actuators that load or unload the sparse wire grid into a position centered on the optical axis of a telescope between the calibration time and CMB observation. Furthermore, the sparse wire grid can be rotated by using a motor. A rotary encoder and a gravity sensor are installed on the sparse wire grid to monitor the wire direction. They allow us to achieve detector polarization angle calibration with an expected systematic error of 0.08°. The calibration system will be installed in small-aperture telescopes at Simons Observatory.

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2023 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2023 Tipo del documento: Article País de afiliación: Japón