Your browser doesn't support javascript.
loading
A biomechanical assessment of tissue-engineered polymer neo-uteri after orthotopic implantation.
Nordberg, Rachel C; Magalhaes, Renata S; Cervelló, Irene; Williams, J Koudy; Atala, Anthony; Loboa, Elizabeth G.
Afiliación
  • Nordberg RC; Joint Department of Biomedical Engineering at University of North Carolina at Chapel Hill and North Carolina State University, Raleigh, North Carolina.
  • Magalhaes RS; Wake Forest Institute for Regenerative Medicine, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
  • Cervelló I; IVI Foundation Research Department, Health Research Institute La Fe, Valencia, Spain.
  • Williams JK; Wake Forest Institute for Regenerative Medicine, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
  • Atala A; Wake Forest Institute for Regenerative Medicine, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
  • Loboa EG; Office of the Provost, Southern Methodist University, Dallas, Texas. Electronic address: egloboa@mail.smu.edu.
F S Sci ; 5(1): 58-68, 2024 Feb.
Article en En | MEDLINE | ID: mdl-38145868
ABSTRACT

OBJECTIVE:

To assess the in vivo biomechanical maturation of tissue-engineered neo-uteri that have previously supported live births in a rabbit model.

DESIGN:

Nonclinical animal study.

SETTING:

University-based research laboratory. ANIMALS Eighteen adult female rabbits. INTERVENTION Biodegradable poly-DL-lactide-co-glycolide-coated polyglycolic acid scaffolds seeded with autologous uterine-derived endometrial and myometrial cells. Nonseeded scaffolds and seeded, tissue-engineered neo-uteri were implanted into one uterine horn of rabbits for 1, 3, or 6 months, excised, and biomechanically assessed in comparison to native uterine tissue. MAIN OUTCOME

MEASURES:

Tensile stress-relaxation testing, strain-to-failure testing, and viscoelastic modeling.

RESULTS:

By evaluating the biomechanical data with several viscoelastic models, it was revealed that tissue-engineered uteri were more mechanically robust than nonseeded scaffolds. For example, the 10% instantaneous stress of the tissue-engineered neo-uteri was 2.1 times higher than the nonseeded scaffolds at the 1-month time point, 1.6 times higher at the 3-month time point, and 1.5 times higher at the 6-month time point. Additionally, as the duration of implantation increased, the engineered constructs became more mechanically robust (e.g., 10% instantaneous stress of the tissue-engineered neo-uteri increased from 22 kPa at 1 month to 42 kPa at 6 months). Compared with native tissue values, tissue-engineered neo-uteri achieved or surpassed native tissue values by the 6-month time point.

CONCLUSION:

The present study evaluated the mechanical characteristics of novel tissue-engineered neo-uteri that have previously been reported to support live births in the rabbit model. We demonstrate that the biomechanics of these implants closely resemble those of native tissue, giving further credence to their development as a clinical solution to uterine factor infertility.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ingeniería de Tejidos / Andamios del Tejido Límite: Animals / Female / Humans / Pregnancy Idioma: En Revista: F S Sci Año: 2024 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ingeniería de Tejidos / Andamios del Tejido Límite: Animals / Female / Humans / Pregnancy Idioma: En Revista: F S Sci Año: 2024 Tipo del documento: Article