Your browser doesn't support javascript.
loading
Comparison of high-resolution mass spectrometry acquisition methods for the simultaneous quantification and identification of per- and polyfluoroalkyl substances (PFAS).
Partington, Jordan M; Rana, Sahil; Szabo, Drew; Anumol, Tarun; Clarke, Bradley O.
Afiliación
  • Partington JM; Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria, 3010, Australia.
  • Rana S; Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria, 3010, Australia.
  • Szabo D; Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria, 3010, Australia.
  • Anumol T; Department of Materials and Environmental Chemistry, Stockholm University, 11418, Stockholm, Sweden.
  • Clarke BO; Agilent Technologies Inc, Wilmington, DE, 19808, USA.
Anal Bioanal Chem ; 416(4): 895-912, 2024 Feb.
Article en En | MEDLINE | ID: mdl-38159142
ABSTRACT
Simultaneous identification and quantification of per- and polyfluoroalkyl substances (PFAS) were evaluated for three quadrupole time-of-flight mass spectrometry (QTOF) acquisition methods. The acquisition methods investigated were MS-Only, all ion fragmentation (All-Ions), and automated tandem mass spectrometry (Auto-MS/MS). Target analytes were the 25 PFAS of US EPA Method 533 and the acquisition methods were evaluated by analyte response, limit of quantification (LOQ), accuracy, precision, and target-suspect screening identification limit (IL). PFAS LOQs were consistent across acquisition methods, with individual PFAS LOQs within an order of magnitude. The mean and range for MS-Only, All-Ions, and Auto-MS/MS are 1.3 (0.34-5.1), 2.1 (0.49-5.1), and 1.5 (0.20-5.1) pg on column. For fast data processing and tentative identification with lower confidence, MS-Only is recommended; however, this can lead to false-positives. Where high-confidence identification, structural characterisation, and quantification are desired, Auto-MS/MS is recommended; however, cycle time should be considered where many compounds are anticipated to be present. For comprehensive screening workflows and sample archiving, All-Ions is recommended, facilitating both quantification and retrospective analysis. This study validated HRMS acquisition approaches for quantification (based upon precursor data) and exploration of identification workflows for a range of PFAS compounds.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Espectrometría de Masas en Tándem / Fluorocarburos Idioma: En Revista: Anal Bioanal Chem Año: 2024 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Espectrometría de Masas en Tándem / Fluorocarburos Idioma: En Revista: Anal Bioanal Chem Año: 2024 Tipo del documento: Article País de afiliación: Australia