Diameters of the optic sheath and superior ophthalmic vein can expand and contract at positional changes: a magnetic resonance imaging study.
Surg Radiol Anat
; 46(2): 153-158, 2024 Feb.
Article
en En
| MEDLINE
| ID: mdl-38189913
ABSTRACT
PURPOSE:
This study aimed to explore the diameters of the optic sheath (OSD) and superior ophthalmic vein (SOVD) in response to positional changes using magnetic resonance imaging (MRI). MATERIALS ANDMETHODS:
Fifty adult outpatients who presented to the hospital underwent thin-slice coronal T2-weighted MRI in the supine position followed by the prone position.RESULTS:
The OS and SOV were well delineated in all the patients. The OSD in the anterior orbit was measured in the supine and prone positions on both sides. In addition, the SOVD in the anterior and posterior orbits was measured in the supine and prone positions on both sides. The OSD demonstrated an increase on both sides in 100% of the cases. The SOVD demonstrated an increase on both sides in 94% of the cases, whereas the remaining 6% demonstrated a decrease. The OSD measured at the anterior orbit and the SOVD at the anterior and posterior orbits significantly increased on both sides with positional changes from the supine to the prone position.CONCLUSION:
OSD and SOVD may expand and contract in response to alterations in the intracranial pressure and venous flow patterns. MRI examination in the supine position combined with positional changes can help to better understand the OS and SOV as dynamic structures.Palabras clave
Texto completo:
1
Bases de datos:
MEDLINE
Asunto principal:
Órbita
/
Imagen por Resonancia Magnética
Límite:
Adult
/
Humans
Idioma:
En
Revista:
Surg Radiol Anat
Asunto de la revista:
ANATOMIA
/
RADIOLOGIA
Año:
2024
Tipo del documento:
Article
País de afiliación: