Your browser doesn't support javascript.
loading
Ultrasensitive and Rapid Detection of Procalcitonin via Waveguide-Enhanced Nanogold-Linked Immunosorbent Assay for Early Sepsis Diagnosis.
Barshilia, Devesh; Huang, Jhen-Jie; Komaram, Akhil Chandrakanth; Chen, Yi-Che; Chen, Chun-Da; Syu, Min-Yu; Chao, Wen-Cheng; Chau, Lai-Kwan; Chang, Guo-En.
Afiliación
  • Barshilia D; Department of Mechanical Engineering, National Chung Cheng University, Chiayi 621301, Taiwan.
  • Huang JJ; Advanced Institute of Manufacturing with High-Tech Innovations (AIM-HI), National Chung Cheng University, Chiayi 621301, Taiwan.
  • Komaram AC; Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi 621301, Taiwan.
  • Chen YC; Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi 621301, Taiwan.
  • Chen CD; Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi 621301, Taiwan.
  • Syu MY; Department of Laboratory Medicine, National Taiwan University Hospital Yunlin Branch, Yunlin 640, Taiwan.
  • Chao WC; Department of Laboratory Medicine, National Taiwan University Hospital Yunlin Branch, Yunlin 640, Taiwan.
  • Chau LK; Department of Critical Care Medicine, Taichung Veterans General Hospital, Taichung 402202, Taiwan.
  • Chang GE; Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi 621301, Taiwan.
Nano Lett ; 24(8): 2596-2602, 2024 Feb 28.
Article en En | MEDLINE | ID: mdl-38251930
ABSTRACT
Sepsis, a life-threatening inflammatory response, demands economical, accurate, and rapid detection of biomarkers during the critical "golden hour" to reduce the patient mortality rate. Here, we demonstrate a cost-effective waveguide-enhanced nanogold-linked immunosorbent assay (WENLISA) based on nanoplasmonic waveguide biosensors for the rapid and sensitive detection of procalcitonin (PCT), a sepsis-related inflammatory biomarker. To enhance the limit of detection (LOD), we employed sandwich assays using immobilized capture antibodies and detection antibodies conjugated to gold nanoparticles to bind the target analyte, leading to a significant evanescent wave redistribution and strong nanoplasmonic absorption near the waveguide surface. Experimentally, we detected PCT for a wide linear response range of 0.1 pg/mL to 1 ng/mL with a record-low LOD of 48.7 fg/mL (3.74 fM) in 8 min. Furthermore, WENLISA has successfully identified PCT levels in the blood plasma of patients with sepsis and healthy individuals, offering a promising technology for early sepsis diagnosis.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Sepsis / Nanopartículas del Metal Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Nano Lett Año: 2024 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Sepsis / Nanopartículas del Metal Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Nano Lett Año: 2024 Tipo del documento: Article País de afiliación: Taiwán