  • Ting HN; Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Jalan Pantai Baharu, 50603 Kuala Lumpur, Malaysia; Faculty of Medical Engineering, Jining Medical University, University Park, National High-tech Zone, 272067 Jining City, Shandong Province, China. Electronic address: tinghn@um.edu.my.
  • Choo YM; Department of Paediatrics, Faculty of Medicine, Universiti Malaya, Jalan Pantai Baharu, 50603 Kuala Lumpur, Malaysia.
Comput Methods Programs Biomed ; 245: 108043, 2024 Mar.
Article en En | MEDLINE | ID: mdl-38306944
ABSTRACT
BACKGROUND AND

OBJECTIVE:

Conflict may happen when more than one classifier is used to perform prediction or classification. The recognition model error leads to conflicting evidence. These conflicts can cause decision errors in a baby cry recognition and further decrease its recognition accuracy. Thus, the objective of this study is to propose a method that can effectively minimize the conflict among deep learning models and improve the accuracy of baby cry recognition.

METHODS:

An improved Dempster-Shafer evidence theory (DST) based on Wasserstein distance and Deng entropy was proposed to reduce the conflicts among the results by combining the credibility degree between evidence and the uncertainty degree of evidence. To validate the effectiveness of the proposed method, examples were analyzed, and applied in a baby cry recognition. The Whale optimization algorithm-Variational mode decomposition (WOA-VMD) was used to optimally decompose the baby cry signals. The deep features of decomposed components were extracted using the VGG16 model. Long Short-Term Memory (LSTM) models were used to classify baby cry signals. An improved DST decision method was used to obtain the decision fusion.

RESULTS:

The proposed fusion method achieves an accuracy of 90.15% in classifying three types of baby cry. Improvement between 2.90% and 4.98% was obtained over the existing DST fusion methods. Recognition accuracy was improved by between 5.79% and 11.53% when compared to the latest methods used in baby cry recognition.

CONCLUSION:

The proposed method optimally decomposes baby cry signal, effectively reduces the conflict among the results of deep learning models and improves the accuracy of baby cry recognition.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ballenas / Algoritmos Tipo de estudio: Prognostic_studies Límite: Animals / Humans / Infant Idioma: En Revista: Comput Methods Programs Biomed Asunto de la revista: INFORMATICA MEDICA Año: 2024 Tipo del documento: Article País de afiliación: Malasia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ballenas / Algoritmos Tipo de estudio: Prognostic_studies Límite: Animals / Humans / Infant Idioma: En Revista: Comput Methods Programs Biomed Asunto de la revista: INFORMATICA MEDICA Año: 2024 Tipo del documento: Article País de afiliación: Malasia