Your browser doesn't support javascript.
loading
Lung impedance changes during awake prone positioning in COVID-19. A non-randomized cross-over study.
Rosén, Jacob; Frykholm, Peter; Jonsson Fagerlund, Malin; Pellegrini, Mariangela; Campoccia Jalde, Francesca; von Oelreich, Erik; Fors, Diddi.
Afiliación
  • Rosén J; Department of Surgical Sciences, Anaesthesiology and Intensive Care Medicine, Uppsala University, Uppsala, Sweden.
  • Frykholm P; Department of Surgical Sciences, Anaesthesiology and Intensive Care Medicine, Uppsala University, Uppsala, Sweden.
  • Jonsson Fagerlund M; Perioperative Medicine and Intensive Care, Karolinska University Hospital, Solna, Sweden.
  • Pellegrini M; Section of Anesthesiology and Intensive Care Medicine, Department of Physiology and Pharmacology, Karolinska Institutet, Solna, Sweden.
  • Campoccia Jalde F; Department of Surgical Sciences, Anaesthesiology and Intensive Care Medicine, Uppsala University, Uppsala, Sweden.
  • von Oelreich E; Perioperative Medicine and Intensive Care, Karolinska University Hospital, Solna, Sweden.
  • Fors D; Section of Thoracic Anesthesiology and Intensive Care, Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden.
PLoS One ; 19(2): e0299199, 2024.
Article en En | MEDLINE | ID: mdl-38381730
ABSTRACT

BACKGROUND:

The effects of awake prone positioning (APP) on respiratory mechanics in patients with COVID-19 are not well characterized. The aim of this study was to investigate changes of global and regional lung volumes during APP compared with the supine position using electrical lung impedance tomography (EIT) in patients with hypoxemic respiratory failure due to COVID-19. MATERIALS AND

METHODS:

This exploratory non-randomized cross-over study was conducted at two university hospitals in Sweden between January and May 2021. Patients admitted to the intensive care unit with confirmed COVID-19, an arterial cannula in place, a PaO2/FiO2 ratio <26.6 kPa (<200 mmHg) and high-flow nasal oxygen or non-invasive ventilation were eligible for inclusion. EIT-data were recorded at supine baseline, at 30 and 60 minutes after APP-initiation, and 30 minutes after supine repositioning. The primary outcomes were changes in global and regional tidal impedance variation (TIV), center of ventilation (CoV), global and regional delta end-expiratory lung-impedance (dEELI) and global inhomogeneity (GI) index at the end of APP compared with supine baseline. Data were reported as median (IQR).

RESULTS:

All patients (n = 10) were male and age was 64 (47-73) years. There were no changes in global or regional TIV, CoV or GI-index during the intervention. dEELI increased from supine reference value 0 to 1.51 (0.32-3.62) 60 minutes after APP (median difference 1.51 (95% CI 0.19-5.16), p = 0.04) and returned to near baseline values after supine repositioning. Seven patients (70%) showed an increase >0.20 in dEELI during APP. The other EIT-variables did not change during APP compared with baseline.

CONCLUSION:

Awake prone positioning was associated with a transient lung recruiting effect without changes in ventilation distribution measured with EIT in patients with hypoxemic respiratory failure due to COVID-19.