Your browser doesn't support javascript.
loading
Diagnostic performance of intravascular ultrasound-based fractional flow reserve in evaluating of intermediate left main stenosis.
Sui, Yong-Gang; Yang, Cheng; Guan, Chang-Dong; Xu, Yan-Lu; Wu, Na-Qiong; Yang, Wei-Xian; Wu, Yong-Jian; Dou, Ke-Fei; Yang, Yue-Jin; Qiao, Shu-Bin; Yu, Wei; Xu, Bo; Tu, Sheng-Xian; Qian, Jie.
Afiliación
  • Sui YG; Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Yang C; Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Guan CD; Catheterization Laboratories, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Xu YL; Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Wu NQ; Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Yang WX; Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Wu YJ; Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Dou KF; Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Yang YJ; Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Qiao SB; Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Yu W; Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Xu B; Catheterization Laboratories, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Tu SX; National Clinical Research Center for Cardiovascular Diseases, Beijing, China.
  • Qian J; Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
J Geriatr Cardiol ; 21(1): 34-43, 2024 Jan 28.
Article en En | MEDLINE | ID: mdl-38440337
ABSTRACT

BACKGROUND:

The recently introduced ultrasonic flow ratio (UFR), is a novel fast computational method to derive fractional flow reserve (FFR) from intravascular ultrasound (IVUS) images. In the present study, we evaluate the diagnostic performance of UFR in patients with intermediate left main (LM) stenosis.

METHODS:

This is a prospective, single center study enrolling consecutive patients with presence of intermediated LM lesions (diameter stenosis of 30%-80% by visual estimation) underwent IVUS and FFR measurement. An independent core laboratory assessed offline UFR and IVUS-derived minimal lumen area (MLA) in a blinded fashion.

RESULTS:

Both UFR and FFR were successfully achieved in 41 LM patients (mean age, 62.0 ± 9.9 years, 46.3% diabetes). An acceptable correlation between UFR and FFR was identified (r = 0.688, P < 0.0001), with an absolute numerical difference of 0.03 (standard difference 0.01). The area under the curve (AUC) in diagnosis of physiologically significant coronary stenosis for UFR was 0.94 (95% CI 0.87-1.01), which was significantly higher than angiographic identified stenosis > 50% (AUC = 0.66, P < 0.001) and numerically higher than IVUS-derived MLA (AUC = 0.82; P = 0.09). Patient level diagnostic accuracy, sensitivity and specificity for UFR to identify FFR ≤ 0.80 was 82.9% (95% CI 70.2-95.7), 93.1% (95% CI 82.2-100.0), 58.3% (95% CI 26.3-90.4), respectively.

CONCLUSION:

In patients with intermediate LM diseases, UFR was proved to be associated with acceptable correlation and high accuracy with pressure wire-based FFR as standard reference. The present study supports the use of UFR for functional evaluation of intermediate LM stenosis.

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: J Geriatr Cardiol Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: J Geriatr Cardiol Año: 2024 Tipo del documento: Article País de afiliación: China