Your browser doesn't support javascript.
loading
Dual-mode sensing strategy based on carbon dots for sensitive and selective detection of molybdate ions.
Zeng, Hui-Hui; Huang, Ren-Xiu; Jiang, Ming-Qiang; Liu, Fang; Shi, Wei-Guo; Chen, Lin.
Afiliación
  • Zeng HH; Jiangxi Key Laboratory of Industrial Ceramics, College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China. zenghuihui1022@163.com.
  • Huang RX; Jiangxi Key Laboratory of Industrial Ceramics, College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China.
  • Jiang MQ; Jiangxi Key Laboratory of Industrial Ceramics, College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China.
  • Liu F; Jiangxi Key Laboratory of Industrial Ceramics, College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China.
  • Shi WG; Jiangxi Key Laboratory of Industrial Ceramics, College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China.
  • Chen L; Jiangxi Key Laboratory of Industrial Ceramics, College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China.
Mikrochim Acta ; 191(4): 187, 2024 Mar 07.
Article en En | MEDLINE | ID: mdl-38453742
ABSTRACT
Two kinds of carbon dots with the maximum fluorescence peak of 492 nm (named as G-CDs) and 607 nm (named as R-CDs) were synthesized. In the presence of MoO42- ions, the fluorescence of R-CDs at 607 nm can be quenched, which can probably be assigned to their aggregation caused by MoO42-, while that of G-CDs at 492 nm remained unchanged. For the first time, a ratiometric fluorescence probe was developed for MoO42- ions detection. In the range 0.25 ~ 100 µM, the fluorescence ratio (F492/F607) of the probe was linearly related to MoO42- concentration, and the detection limit was 61.5 nM, which fully meets the minimum detection requirements of MoO42- ions in drinking water. On the other hand, when MoO42- was introduced, a significant fading phenomenon of R-CDs can be observed with the naked eye; thereby, the colorimetric method can also be proposed. Based on above, the ratiometric fluorometric/colorimetric dual-mode sensing method was established for MoO42- anion quantification. Compared with the traditional analysis methods, the results obtained by multimodal sensing can be mutually verified, which effectively improves the accuracy and reliability. The dual-mode assay proposed in this work provides an alternative scheme to meet the need of sensing target compounds in complex matrices.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article País de afiliación: China