Your browser doesn't support javascript.
loading
Evaluation of Aortic Hemodynamics Using Four-Dimensional Flow of Magnetic Resonance Imaging in Rabbits with Liver Fibrosis.
Li, Jiali; Li, Yuansheng; Lin, Xin; Lv, Cheng; Zhang, Xiaoyong; Chen, Jing.
Afiliación
  • Li J; Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
  • Li Y; School of Public Health, Southern Medical University, Guangzhou, Guangdong, China.
  • Lin X; Department of Otolaryngology Head and Neck Surgery, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
  • Lv C; Department of General Surgery, The Second Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, China.
  • Zhang X; Clinical Science, Philips Healthcare, Chengdu, Sichuan, China.
  • Chen J; Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
J Magn Reson Imaging ; 2024 Mar 23.
Article en En | MEDLINE | ID: mdl-38520716
ABSTRACT

BACKGROUND:

Liver fibrosis (LF) precipitates systemic hemodynamic alterations, however, its impact on the aorta remaining undefined.

PURPOSE:

To assess aorta hemodynamics changes during LF development in a rabbit model. STUDY TYPE Prospective, experimental. ANIMAL MODEL Thirty 7-month-old male rabbits underwent bile duct ligation (BDL) to induce LF. FIELD STRENGTH/SEQUENCE Biweekly four-dimensional (4D) flow imaging incorporating a 3D gradient-echo at 3.0 T scanner for 14 weeks post-BDL. ASSESSMENT Histopathological exams for 2-5 rabbits were performed at each time point, following each MRI scan. LF was graded using the Metavir scale by a pathologist. 4D flow was analyzed by two radiologists using dedicated postprocessing software. They recorded 4D flow parameters at four aorta sections (aortic sinus, before and after bifurcation of aortic arch, and descending aorta). STATISTICAL TESTS The linear mixed model; Bonferroni correction; Pearson correlation coefficient (r); receiver operating characteristic (ROC) curve; Delong test. The level of significance was set at P < 0.05.

RESULTS:

Following BDL, the wall shear stress (WSS) (0.23-0.32 Pa), energy loss (EL) (0.27-1.55 mW) of aorta significantly increased at the second week for each plane, peaking at the sixth week (WSS 0.35-0.49 Pa, EL 0.57-2.0 mW). So did the relative pressure difference (RPD) (second week 1.67 ± 1.63 mmHg, sixth week 2.43 ± 0.63 mmHg) in plane 2. Notably, the RPD in plane 2 at the second week displayed the highest area under ROC curve of 0.998 (specificity 1, sensitivity 0.967). LF were found at the second, fourth, and sixth week after BDL, with grade F2, F3, and F4, respectively. The RPD in plane 2 was most strongly correlated with the severity of LF (r = 0.86). DATA

CONCLUSIONS:

The occurrence of LF could increase WSS, EL, and RPD of aorta as early as the second week following BDL. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY Stage 2.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: China