Your browser doesn't support javascript.
loading
A highly sensitive and long-term stable wearable patch for continuous analysis of biomarkers in sweat.
Lorestani, Farnaz; Zhang, Xianzhe; Abdullah, Abu Musa; Xin, Xin; Liu, Yushen; Rahman, Mashfiqur; Biswas, Md Abu Sayeed; Li, Bowen; Dutta, Ankan; Niu, Zhenyuan; Das, Shuvendu; Barai, Shishir; Wang, Ke; Cheng, Huanyu.
Afiliación
  • Lorestani F; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Zhang X; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Abdullah AM; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Xin X; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Liu Y; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Rahman M; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Biswas MAS; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Li B; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Dutta A; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Niu Z; Center for Neural Engineering, The Pennsylvania State University, University Park, PA, 16802, USA.
  • Das S; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Barai S; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Wang K; Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA,16802, USA.
  • Cheng H; Materials Research Institute, The Pennsylvania State University, University Park, PA 16802.
Adv Funct Mater ; 33(52)2023 Dec 22.
Article en En | MEDLINE | ID: mdl-38525448
ABSTRACT
Although increasing efforts have been devoted to the development of non-invasive wearable or stretchable electrochemical sweat sensors for monitoring physiological and metabolic information, most of them still suffer from poor stability and specificity over time and fluctuating temperatures. This study reports the design and fabrication of a long-term stable and highly sensitive flexible electrochemical sensor based on nanocomposite-modified porous graphene by simple and facile laser treatment for detecting biomarkers such as glucose in sweat. The laser-reduced and patterned stable conductive nanocomposite on the porous graphene electrode provides the resulting glucose sensor with an excellent sensitivity of 1317.69 µAmM-1cm-2 with an ultra-low limit of detection (LOD) of 0.079 µM. The sensor can also detect pH and exhibit extraordinary stability to maintain more than 91% sensitivity over 21 days in ambient conditions. Taken together with a temperature sensor based on the same material system, the dual glucose and pH sensor integrated with a flexible microfluidic sweat sampling network further results in accurate continuous on-body glucose detection calibrated by the simultaneously measured pH and temperature. The low-cost, highly sensitive, and long-term stable platform could facilitate and pave the way for the early identification and continuous monitoring of different biomarkers for non-invasive disease diagnosis and treatment evaluation.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Adv Funct Mater Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Adv Funct Mater Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos