Hardware and Software Setup for Quantitative 23Na Magnetic Resonance Imaging at 3T: A Phantom Study.
Giovannetti, Giulio; Flori, Alessandra; Martini, Nicola; Cademartiri, Filippo; Aquaro, Giovanni Donato; Pingitore, Alessandro; Frijia, Francesca.
Afiliación
  • Giovannetti G; Institute of Clinical Physiology, National Council of Research, Via G. Moruzzi 1, 56124 Pisa, Italy.
  • Flori A; Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy.
  • Martini N; Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy.
  • Cademartiri F; Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy.
  • Aquaro GD; Department of Surgical, Medical, Molecular and Critical Area Pathology, University of Pisa, 56126 Pisa, Italy.
  • Pingitore A; Institute of Clinical Physiology, National Council of Research, Via G. Moruzzi 1, 56124 Pisa, Italy.
  • Frijia F; Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy.
Sensors (Basel) ; 24(9)2024 Apr 24.
Article en En | MEDLINE | ID: mdl-38732822
ABSTRACT
Magnetic resonance (MR) with sodium (23Na) is a noninvasive tool providing quantitative biochemical information regarding physiology, cellular metabolism, and viability, with the potential to extend MR beyond anatomical proton imaging. However, when using clinical scanners, the low detectable 23Na signal and the low 23Na gyromagnetic ratio require the design of dedicated radiofrequency (RF) coils tuned to the 23Na Larmor frequency and sequences, as well as the development of dedicated phantoms for testing the image quality, and an MR scanner with multinuclear spectroscopy (MNS) capabilities. In this work, we propose a hardware and software setup for evaluating the potential of 23Na magnetic resonance imaging (MRI) with a clinical scanner. In particular, the reliability of the proposed setup and the reproducibility of the measurements were verified by multiple acquisitions from a 3T MR scanner using a homebuilt RF volume coil and a dedicated sequence for the imaging of a phantom specifically designed for evaluating the accuracy of the technique. The final goal of this study is to propose a setup for standardizing clinical and research 23Na MRI protocols.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Programas Informáticos / Imagen por Resonancia Magnética / Fantasmas de Imagen Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Programas Informáticos / Imagen por Resonancia Magnética / Fantasmas de Imagen Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Italia