Your browser doesn't support javascript.
loading
Vein of Marshall chemical ablation decreases atrial fibrillation drivers detected by CARTOFINDER.
Hasebe, Hideyuki; Furuyashiki, Yoshitaka; Yoshida, Kentaro.
Afiliación
  • Hasebe H; Department of Cardiology, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.
  • Furuyashiki Y; Department of Arrhythmology, Shizuoka Saiseikai General Hospital, Shizuoka, Japan.
  • Yoshida K; Department of Arrhythmology, Shizuoka Saiseikai General Hospital, Shizuoka, Japan.
J Cardiovasc Electrophysiol ; 35(7): 1461-1470, 2024 Jul.
Article en En | MEDLINE | ID: mdl-38769635
ABSTRACT

INTRODUCTION:

This study sought to elucidate the impact of vein of Marshall (VOM) chemical ablation on atrial fibrillation (AF) drivers by investigating the changes in CARTOFINDER mappings before and after VOM chemical ablation in patients with persistent AF.

METHODS:

This study included 23 consecutive patients undergoing catheter ablation for long-persistent AF (>18 months). VOM chemical ablation was performed following pulmonary vein isolation. CARTOFINDER and AF cycle length (AFCL) maps were created in the left atrium (LA) before and after VOM chemical ablation. The LA was divided into 8 segments, and the number of focal activation points with 6 or more repetitions was counted in each segment.

RESULTS:

The number of focal activation points was largest in the LA appendage (LAA). After VOM chemical ablation, the number of focal activation points in the LA decreased significantly (37 [interquartile range, IQR 19-55] vs. 15 [IQR 7-21], p < .001), and median AFCL was significantly prolonged (159 [147-168] vs. 164 [150-173] ms, p < .001). In the assessment of each segment, significant decreases in focal activation points were observed in the inferior, lateral, and anterior segments and LAA. Among the focal activation points disappearing after chemical ablation, the number in the non-ethanol-affected area was significantly larger than that in the affected area (13 [8-25] vs. 4 [1-10], p < .001).

CONCLUSIONS:

VOM chemical ablation decreases AF drivers detected by CARTOFINDER. Mechanisms other than direct myocardial damage are considered to contribute the attenuation of AF drivers.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Venas Pulmonares / Fibrilación Atrial / Potenciales de Acción / Valor Predictivo de las Pruebas / Ablación por Catéter / Técnicas Electrofisiológicas Cardíacas / Frecuencia Cardíaca Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Venas Pulmonares / Fibrilación Atrial / Potenciales de Acción / Valor Predictivo de las Pruebas / Ablación por Catéter / Técnicas Electrofisiológicas Cardíacas / Frecuencia Cardíaca Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón