Your browser doesn't support javascript.
loading
Innovative hydrogel-patch combination for large annulus fibrosus defects: a prospective approach to address herniation recurrence.
Nie, Mao-Dan; Li, Na; Huang, Ze-Bin; Cheng, Rong-Shan; Zhang, Qiang; Fu, Ling-Jie; Cheng, Cheng-Kung.
Afiliación
  • Nie MD; School of Biomedical Engineering, Shanghai Jiao Tong University, No. 1954 Huashan Road, Xuhui District, Shanghai, 200030, China.
  • Li N; Department of Absorbable Materials Research and Development, Beijing Naton Medical Institute, No.9 Chengwan Street, Haidian District, Beijing, 100143, China.
  • Huang ZB; Department of Spine Surgery, First Affiliated Hospital of Second Military Medical University, No. 168 Changhai Road, Yangpu District, Shanghai, 200433, China.
  • Cheng RS; School of Biomedical Engineering, Shanghai Jiao Tong University, No. 1954 Huashan Road, Xuhui District, Shanghai, 200030, China.
  • Zhang Q; School of Biomedical Engineering, Shanghai Jiao Tong University, No. 1954 Huashan Road, Xuhui District, Shanghai, 200030, China.
  • Fu LJ; Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, No. 639, Manufacturing Bureau Road, Huangpu District, Shanghai, 200011, China.
  • Cheng CK; School of Biomedical Engineering, Shanghai Jiao Tong University, No. 1954 Huashan Road, Xuhui District, Shanghai, 200030, China. Electronic address: ckcheng2020@sjtu.edu.cn.
Spine J ; 2024 Jun 23.
Article en En | MEDLINE | ID: mdl-38914373
ABSTRACT
BACKGROUND CONTEXT Large annulus fibrosus (AF) defects often lead to a high rate of reherniation, particularly in the medial AF region, which has limited self-healing capabilities. The increasing prevalence of herniated discs underscores the need for effective repair strategies.

PURPOSE:

The objectives of this study were to design an AF repair technique to reduce solve the current problems of insufficient mechanical properties and poor sealing capacity. STUDY

DESIGN:

In vitro biomechanical experiments and finite element analysis.

METHODS:

The materials used in this study were patches and hydrogels with good biocompatibility and sufficient mechanical properties to withstand loading in the lumbar spine. Five repair techniques were assessed in this study hydrogel filler (HF), AF patch medial barrier (MB), AF patch medial barrier and hydrogel filler (MB&HF), AF patch medial-lateral barrier (MLB), and AF patch medial-lateral barrier and hydrogel filler (MLB&HF). The repair techniques were subjected to in vitro testing (400 N axial compression and 0-500 N fatigue loading at 5Hz) and finite element analysis (400 N axial compression) to evaluate the effectiveness at repairing large AF defects. The evaluation included repair tightness, spinal stability, and fatigue resistance.

RESULTS:

From the in vitro testing, the failure load of the repair techniques was in the following order HF intervertebral disc (IVD) stiffness, resulting in a reduction in spatial stability. The MLB, MB&HF, and MLB&HF groups partially restored IVD stiffness, with MLB&HF showing the most effective recovery (-24.13% ± 3.59%). From the finite element models, incorporating a hydrogel filler was best able to maintain the IVD height. Patch repair alone could not adequately reduce the high AF stress due to AF injury, but with hydrogel support, stress was substantially low and more uniformly distributed. All repair techniques demonstrated reduced stress around the damaged area on the AF, in comparison to the unrepaired model. The NP pressure in the HF group was closest to the intact group, and the patch repair reduced the NP pressure. The maximum patch deformation and suture stress were ranked as MB >MLB >MB&HF >MLB&HF.

CONCLUSIONS:

The combined use of patches and hydrogels exhibited promising mechanical properties postdiscectomy, providing a promising solution for addressing large AF defects and improving disc stability. CLINICAL

SIGNIFICANCE:

This study introduces a promising method for repairing large annular fissure (AF) defects after disc herniation, combining patch repair with a hydrogel filler. These techniques hold potential for developing clinical AF repair products to address this challenging issue.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Spine J Asunto de la revista: ORTOPEDIA Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Spine J Asunto de la revista: ORTOPEDIA Año: 2024 Tipo del documento: Article País de afiliación: China