Your browser doesn't support javascript.
loading
Fewer Dislocations After Total Hip Arthroplasty With Robotic Assistance or Fluoroscopic Guidance.
Di Gangi, Catherine; Prinos, Alana; Buehring, Weston; Meere, Patrick A; Meftah, Morteza; Hepinstall, Matthew S.
Afiliación
  • Di Gangi C; Department of Orthopaedic Surgery, NYU Langone Health, New York, New York.
  • Prinos A; Department of Orthopaedic Surgery, NYU Langone Health, New York, New York.
  • Buehring W; Department of Orthopaedic Surgery, NYU Langone Health, New York, New York.
  • Meere PA; Department of Orthopaedic Surgery, NYU Langone Health, New York, New York.
  • Meftah M; Department of Orthopaedic Surgery, NYU Langone Health, New York, New York.
  • Hepinstall MS; Department of Orthopaedic Surgery, NYU Langone Health, New York, New York.
J Arthroplasty ; 39(9S2): S359-S366, 2024 Sep.
Article en En | MEDLINE | ID: mdl-39002766
ABSTRACT

BACKGROUND:

Computer navigation and robotic assistance may reduce total hip arthroplasty (THA) dislocations by improving the accuracy and precision of component positioning. We investigated dislocation rates for THAs using conventional techniques, robotic assistance, and computer navigation, while controlling for surgical approach, dual mobility (DM) use, and fluoroscopic guidance.

METHODS:

We reviewed 11,740 primary THAs performed between June 2016 and December 2022, including 5,873 conventional, 1,293 with robotic-arm assistance, and 4,574 with navigation. The approach was posterior in 6,580 (56.0%), anterior in 4,342 (37.0%), and lateral in 818 (7.0%). A DM was used in 10.4%. Fluoroscopy was used in 3,653 cases and only with the anterior approach. Multivariate analyses yielded odds ratios (OR) for dislocation and revision. Additional regression analyses for dislocation were performed for approach and DM.

RESULTS:

Raw dislocation rates were as follows conventional 1.2%, robotic 0.4%, navigation 0.9%, anterior with fluoroscopy 0.4%, anterior without fluoroscopy 2.3%, posterior 1.3%, and lateral 0.5%. Upon multivariate analysis, use of robotics was found to be associated with significantly reduced dislocation risk compared to conventional (OR 0.3), as did anterior (OR 0.6) compared to posterior approach; navigation and lateral approach were not found to be associated with a significant reduction in risk. For the anterior approach, multivariate analysis demonstrated that fluoroscopy significantly reduced dislocation risk (OR 0.1), while DM, robotics, and navigation were not significant. For the posterior approach, the dislocation risk was lower with robotics than with conventional (OR 0.2); the use of navigation or DM did not demonstrate a significant reduction in risk.

CONCLUSIONS:

The use of robotics was associated with a reduction in dislocations for this cohort overall. Further, fluoroscopy in the anterior approach and robotic assistance in the posterior approach were both associated with decreased dislocation risk. The role of imageless computer navigation and DM implants requires further study.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Cirugía Asistida por Computador / Procedimientos Quirúrgicos Robotizados Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2024 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Cirugía Asistida por Computador / Procedimientos Quirúrgicos Robotizados Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2024 Tipo del documento: Article