Your browser doesn't support javascript.
loading
Lung volume reduction surgery for pulmonary emphysema using dynamic Xenon-133 and Tc-99m-MAA SPECT images.
Sugi, K; Matsuoka, T; Tanaka, T; Sakano, H; Nawata, K; Ueda, K; Fujita, N; Kaneda, Y; Esato, K.
Afiliación
  • Sugi K; First Department of Surgery, Yamaguchi University School of Medicine, 1144 Kogushi, Ube, Yamaguchi 755-8505, Japan.
Ann Thorac Cardiovasc Surg ; 4(3): 149-53, 1998 Jun.
Article en En | MEDLINE | ID: mdl-9660913
ABSTRACT
The usefulness of Xe-133 and Tc-99m-MAA single photon emission computed tomography (SPECT) in identifying areas to be resected during video-assisted thoracoscopic lung reduction surgery for emphysema was examined. Twenty-nine patients with advanced emphysema were examined using Xe-133 and Tc-99m-MAA SPECT prior to and following surgery. For the Xe-133 dynamic SPECT, patients inhaled Xe-133 gas for 6 minutes. Equilibrium and subsequent washout SPECT images were acquired every 30 seconds for 6 to 7 minutes during spontaneous breathing. Ventilation was quantified by Xe-133 clearance time (T1/2) in addition to visual assessment. The patients underwent unilateral thoracoscopic volume reduction in the regions with abnormal Xe-133 retention and Tc-99m-MAA defect. All patients demonstrated marked, heterogeneous Xe-133 retention and Tc-99m-MAA defects preoperatively. The worst functioning areas were identified as nonventilated and noflow areas, or areas with air trapping and low perfusion. These changes were found even in patients with diffuse and symmetrical impairments on chest CT. After surgery, most of these "target areas" disappeared and pulmonary function tests demonstrated significant improvement. T1/2 correlated closely with the percent predicted FEV1 (%FEV) and 6-minute walk distance before and after surgery (p<0.0001). Xe-133 and Tc-99m-MAA SPECT imaging was useful in identifying "target areas" in the emphysematous lung. Directed unilateral thoracoscopic volume reduction based on these SPECT images is an effective treatment for emphysema.
Asunto(s)
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Neumonectomía / Enfisema Pulmonar / Radioisótopos de Xenón / Tomografía Computarizada de Emisión de Fotón Único / Agregado de Albúmina Marcado con Tecnecio Tc 99m / Radiofármacos Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: Ann Thorac Cardiovasc Surg Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 1998 Tipo del documento: Article País de afiliación: Japón
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Neumonectomía / Enfisema Pulmonar / Radioisótopos de Xenón / Tomografía Computarizada de Emisión de Fotón Único / Agregado de Albúmina Marcado con Tecnecio Tc 99m / Radiofármacos Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: Ann Thorac Cardiovasc Surg Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 1998 Tipo del documento: Article País de afiliación: Japón