Sensors (Basel) ; 22(8)2022 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-35458887

RESUMO

Significant progress has been made in the field of micro/nano-retinal implant technologies. However, the high pixel range, power leakage, reliability, and lifespan of retinal implants are still questionable. Active implantable devices are safe, cost-effective, and reliable. Although a device that can meet basic safety requirements set by the Food and Drug Administration and the European Union is reliable for long-term use and provides control on current and voltage parameters, it will be expensive and cannot be commercially successful. This study proposes an economical, fully controllable, and configurable wireless communication system based on field-programmable gated arrays (FPGAs) that were designed with the ability to cope with the issues that arise in retinal implantation. This system incorporates hexagonal biphasic stimulation pulses generated by a digital controller that can be fully controlled using an external transmitter. The integration of two separate domain analog systems and a digital controller based on FPGAs is proposed in this study. The system was also implemented on a microchip and verified using in vitro results.


Assuntos
Próteses e Implantes , Retina , Desenho de Equipamento , Reprodutibilidade dos Testes , Telemetria/métodos , Tecnologia sem Fio
2.
Sensors (Basel) ; 19(3)2019 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-30696016

RESUMO

This paper presents a fully integrated photodiode-based low-power and low-mismatch stimulator for a subretinal prosthesis. It is known that a subretinal prosthesis achieves 1600-pixel stimulators on a limited single-chip area that is implanted beneath the bipolar cell layer. However, the high-density pixels cause high power dissipation during stimulation and high fabrication costs because of special process technologies such as the complementary metal-oxide semiconductor CMOS image sensor process. In addition, the many residual charges arising from the high-density pixel stimulation have deleterious effects, such as tissue damage and electrode corrosion, on the retina tissue. In this work, we adopted a switched-capacitor current mirror technique for the single-pixel stimulator (SPStim) that enables low power consumption and low mismatch in the subretinal device. The customized P+/N-well photodiode used to sense the incident light in the SPStim also reduces the fabrication cost. The 64-pixel stimulators are fabricated in a standard 0.35-µm CMOS process along with a global digital controller, which occupies a chip area of 4.3 × 3.2 mm² and are ex-vivo demonstrated using a dissected pig eyeball. According to measured results, the SPStim accomplishes a maximum biphasic pulse amplitude of 143 µA, which dissipates an average power of 167 µW in a stimulation period of 5 ms, and an average mismatch of 1.12 % between the cathodic and anodic pulses.


Assuntos
Implantação de Prótese/métodos , Retina/fisiopatologia , Células Bipolares da Retina/patologia , Próteses Visuais , Animais , Técnicas Biossensoriais , Humanos , Luz , Células Bipolares da Retina/fisiologia , Semicondutores , Suínos