Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Molecules ; 29(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38257346

RESUMO

Cystic fibrosis (CF) is a genetic disorder that alters chloride transport in mucous membranes. Recent studies have demonstrated that treatment with modulators of the chloride channel reduces inflammatory markers, restoring, among others, the imbalance of lipids. In this study, we analyzed the serum samples of treated and non-treated patients with modulators with Raman spectroscopy. Nineteen (eight treated an eleven non-treated) patients were considered. The main difference between the two groups appeared in the 3020-2800 cm-1 range. A Voigt deconvolution fit was performed, and nine sub-bands were identified. To distinguish between treated and non-treated patients, the area ratio between the CH3 and CH2 vibration modes was calculated for each patient. The results were validated using statistical analyses. In particular, receiver operating characteristic (ROC) curves and Youden index (Y) were calculated (Area Under Curve (AUC): 0.977; Y: 3.30). An ROC curve represents the performance of the classification, illustrating the diagnostic ability of Raman spectroscopy. It was demonstrated that Raman spectroscopy is able to highlight peculiar differences between elexacaftor/tezacaftor/ivacaftor (ETI)-treated and non-treated patients, in relation with lipids biomarkers.


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística , Fibrose Cística , Humanos , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Fibrose Cística/tratamento farmacológico , Fibrose Cística/genética , Projetos Piloto , Análise Espectral Raman , Lipídeos
2.
J Therm Biol ; 108: 103281, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36031209

RESUMO

In clinical practice, an important aspect of animal health status evaluation is the body temperature recording obtained using different methods. Within them, the non-contact and non-invasive infrared thermometer can provide an accurate estimation of body temperature improving the quality of care and medical decision. To evaluate the use of the monitoring of auricular temperature to improve the quality of care and medical decision. To evaluate the use of the monitoring of auricular temperature as indices of body temperature, as well as rectal temperature in eleven clinically healthy mixed bred cats, eleven Rottweiler dogs, and eleven Italian saddle horses temperature values were obtained by means of an infrared thermometer in the left and right ears and by means of a digital thermometer in the rectum. Two-way analysis of variance (ANOVA) indicated a statistically higher rectal temperature value than the temperature recorded in the left and right ears (P<0.001). In all species, no differences between the right and left ear were recorded (p>0.05). Cats and dogs showed a statistically higher auricular (p<0.001) and rectal (p<0.01) temperature compared to horses. No differences were observed between cats and dogs (p>0.05). Auricular and rectal temperature agreement was shown by the Bland-Altman test. Between the two methods, the average difference was 1.6 °C for cats, 1.4 °C for dogs, and 3.3 °C for horses. In dogs, rectal and auricular temperature showed a positive correlation (r2=0.78). In conclusion, only in healthy dogs maintained in controlled conditions the monitoring of auricular temperature reflects the clinical practice gold standard of core body temperature measurement represented by rectal temperature. The lower value of about 1.5 °C must be taken into consideration when this technique is used.


Assuntos
Temperatura Corporal , Termômetros , Animais , Gatos , Cães , Orelha , Nível de Saúde , Cavalos , Reto , Temperatura
3.
Molecules ; 26(4)2021 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-33669321

RESUMO

This study was aimed at preparing and characterizing solid lipid nanoparticles loading rutin (RT-SLNs) for the treatment of oxidative stress-induced diseases. Phospholipon 80H® as a solid lipid and Polysorbate 80 as surfactant were used for the SLNs preparation, using the solvent emulsification/diffusion method. We obtained spherical RT-SLNs with low sizes, ranging from 40 to 60 nm (hydrodynamic radius) for the SLNs prepared starting from 2% and 5% (w/w) theoretical amount. All prepared formulations showed negative zeta-potential values. RT was efficiently encapsulated within SLNs, obtaining high encapsulation efficiency and drug content percentages, particularly for SLNs prepared with a 5% theoretical amount of RT. In vitro release profiles and analysis of the obtained data applying different kinetic models revealed Fickian diffusion as the main mechanism of RT release from the SLNs. The morphology of RT-SLNs was characterized by scanning electron microscopy (SEM), whereas the interactions between RT and the lipid matrix were investigated by Raman spectroscopy, evidencing spectral modifications of characteristic bands of RT due to the establishment of new interactions. Finally, antioxidant activity assay on human glioblastoma astrocytoma (U373) culture cells showed a dose-dependent activity for RT-SLNs, particularly at the highest assayed dose (50 µM), whereas the free drug showed the lesser activity.


Assuntos
Lipídeos/química , Nanopartículas/química , Rutina/farmacologia , Antioxidantes/farmacologia , Bioensaio , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Liberação Controlada de Fármacos , Humanos , Hidrodinâmica , Nanopartículas/ultraestrutura , Análise de Regressão , Análise Espectral Raman , Eletricidade Estática
4.
Radiol Med ; 124(5): 368-374, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30542910

RESUMO

Carotid atherosclerosis is very important in the pathogenesis of cerebral ischemia. Ultrasonography (US) and magnetic resonance imaging (MRI) are the predominant noninvasive techniques capable to identify the presence and stage of intra-plaque hemorrage. In this work, we propose a novel dedicated phantom that can be used for both US and MRI scanners to evaluate carotid atherosclerotic lesions. The phantom consists of a polymethyl metacrylate (PMMA) diagonally crossed by a PMMA hollow cylinder simulating a blood vessel. To simulate a stenosis, we inserted a plastic hollow tube inside the cylinder. Quantitative image analysis, based on accuracy measurements, was performed on two US and two MRI scanners. The accuracy measurements have highlighted the use of the 3.0 T MRI scanner to characterize the vessel stenosis. However, no significant difference between US and MRI techniques was found in Fisher exact test and inter-rater agreement. The concordance correlation coefficient showed a moderate agreement between some methods. Agreement between 3.0 T and other methods results poor, and this could be due to the fact that the 3.0 T has a better resolution compared to a US and MR 1.5 T. These methods seem to have similar efficacies for the evaluation of vessel stenosis, legitimizing the use of the developed phantom as a versatile and reproducible instrument that could be used during quality controls programs.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ultrassonografia/métodos , Humanos
5.
Fish Physiol Biochem ; 45(3): 943-954, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30627834

RESUMO

Teleost haemoglobins vary in polymorphisms and primary structure, although display similar functional properties. Key amino acids for Root effect (a reduction in oxygen-carrying capacity and loss of cooperativity with declining pH) are conserved throughout fish evolution. For the first time, we cloned and characterised Sparus aurata L. embryonic globin chains (eα1, eα2, eß). We also studied haemoglobins (eHbI, eHbII) behaviour in normal and low-oxygen conditions. Several amino acids in fry globins are different in chemical type (e.g. polar → non-polar and vice versa), compared to adult globins. His55α1, crucial for Root effect, is substituted by Ala in fry, presumably enhancing oxygen capture, transport and reducing the dependence of Root effect from pH. Phylogenetic trees demonstrate that eα1 globin diversified more recently than eα2; moreover, eα1, eα2 and eß globins evolved earlier than adult α and ß globins. In low-oxygen conditions, fry haemoglobins display the same behaviour of the adult haemoglobins (probably, embryonic and adult-type I Hbs display a higher oxygen affinity than type II Hbs, operating through a rapid cycle of heme-Fe auto-oxidation/reduction). Therefore, based on our results and on the comparison with adult haemoglobins, we hypothesise that embryonic haemoglobins have evolved to better adapt fry to variable habitats. We studied Sparus aurata for its economical relevance in Mediterranean aquaculture. The information we provide can help understand Sparus aurata behaviour in the wild and in rearing conditions. Further studies with functional assays will deepen the knowledge on the molecular mechanisms of fry haemoglobin physiology.


Assuntos
Embrião não Mamífero/metabolismo , Regulação da Expressão Gênica no Desenvolvimento/fisiologia , Hemoglobinas/metabolismo , Oxigênio/metabolismo , Dourada/embriologia , Sequência de Aminoácidos , Animais , Evolução Biológica , Proteínas de Peixes , Hemoglobinas/genética , Hipóxia , Dourada/metabolismo
6.
Radiol Med ; 119(3): 208-13, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24337753

RESUMO

PURPOSE: In an attempt to evaluate the exposure level of magnetic resonance imaging (MRI) workers to static magnetic fields, the isotropic magnetic flux density values were integrated over time to produce the cumulative exposure. To protect occupational staff a further precautionary step is proposed by introducing a weighting function incorporating the limits imposed by the Italian legislation. The results obtained should be reported, at the end of each working day, on a special dose card, in order to record each worker's exposure to the static magnetic field. Moreover, this dose card could be an important tool if long-term effects occur because it provides a complete history of the occupational exposure in an MRI site. MATERIALS AND METHODS: To conduct measurements, three Hall-sensor probes were used. The consistency of experimental data, tools and methodologies used was evaluated by performing the Kruskal-Wallis test. Finally, the weighted magnitude of the magnetic flux density was integrated over time to obtain global exposure. RESULTS: Measurements were performed on different MRI scanners ranging from 0.25 up to 3.0 T. The results obtained were compared with the 200 mT·h, which represents the upper limit of the Italian regulation. In no case was the 200 mT·h per day exposure exceeded: however, when the strength of the magnetic field was >200 mT the weighted function overestimated the exposure, so that it represents a highly precautionary measure taking into account possible acute and long-term effects. In addition, from the data recorded during patient positioning operations by MRI staff the dB/dt curve was obtained. CONCLUSIONS: The areas obtained from the integral of the weighted static magnetic field strength over time can be indicative of the global exposure of the occupational staff. These values should be reported on a special dose card that could be considered as an important tool if long-term effects occur because it provides a complete history of the occupational exposure in an MRI site.


Assuntos
Campos Eletromagnéticos/efeitos adversos , Imageamento por Ressonância Magnética , Exposição Ocupacional , Gestão da Segurança , União Europeia , Guias como Assunto , Humanos , Itália , Exposição Ocupacional/legislação & jurisprudência , Gestão da Segurança/legislação & jurisprudência
7.
Animals (Basel) ; 14(13)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38997989

RESUMO

The aim of the present study was to investigate eye temperature modifications after road transport in athletic horses habituated to travel. Eight adult Italian saddle horses traveled 100 km and, two weeks later, 300 km. Eye temperature (ET), rectal temperature (RT) and serum cortisol concentration were assessed before (T1), after (T2) and 60 min (T3) after the road transport. ET was evaluated with infrared thermography (IRT) in three regions of interest: EL1 (medial canthus), EL2 (central cornea) and EL3 (lateral canthus). Two-way analysis of variance (ANOVA) for repeated measures showed statistically higher values at T2 and T3 for EL1 (p < 0.01), EL2 (p < 0.01) and EL3 (p < 0.01) following the 100 km journey. RT (p < 0.01) showed higher values at T2 and T3 after the 100 km journey and higher values at T2 (p < 0.01) following the 300 km journey. ET values were positively correlated with RT at T1, T2 and T3 following the 100 km journey and at T2 following the 300 km journey and positively correlated with serum cortisol concentration at T1, T2 and T3 following the 100 km journey and at T2 and T3 following the 300 km journey. Eye temperature monitoring with IRT allows quick and practical strategies to monitor an animal's physiological state and welfare during daily activities.

8.
J Equine Vet Sci ; 138: 105102, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38815839

RESUMO

This study aimed to evaluate changes in body temperature in athletic horses during two different road transport distances. Six Italian Saddle horses were subjected to a 100 and 300 km transport during different times of day (am and pm). Rectal and cutaneous temperatures were recorded before (T0), immediately (following 5 min- T1) and 1 hour (T2) after transport by means of a rectal digital thermometer and a thermal infrared camera (FLIR T440) respectively, for the evaluation of left and right side of four body regions: jugular, shoulder, croup and inner thigh. There were no differences between left and right sides, inner thigh or rectal temperatures when comparing the transport distance, time points or time of day. At T0, jugular (P < 0.0001), shoulder (P < 0.01) and croup (P < 0.01) average temperatures were higher in the pm compared to those in the am in both journeys. At T1, jugular (P < 0.01) and croup (P < 0.01) temperatures were lower in the pm compared to am following the 300 km journey. Jugular temperature (P < 0.0001) was higher following the 300 km compared to the 100 km journey at each time point (T1 and T2) at both times of day (am and pm). Shoulder (P < 0.0001) and croup temperatures (P < 0.0001) were higher at T2 after the 300 km journey than at T2 after the 100 km journey). The current results suggested a difference between the two distances and the time of day appeared to have as great effect on ocular temperature as road transport distance.


Assuntos
Temperatura Corporal , Termografia , Animais , Cavalos/fisiologia , Termografia/métodos , Termografia/instrumentação , Temperatura Corporal/fisiologia , Raios Infravermelhos , Meios de Transporte , Masculino , Homeostase/fisiologia , Condicionamento Físico Animal/fisiologia , Feminino
9.
Diagnostics (Basel) ; 14(13)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-39001299

RESUMO

During magnetic-resonance-guided focused ultrasound ablation of the ventral intermediate thalamic nucleus (VIM) for essential tremor (ET) and Parkinson's disease (PD), targeting is generally performed using a standard atlas-based stereotactic approach. The purpose of our work is to evaluate the anatomic variations in the venous vasculature of the thalamus in patients treated with MRgFUS, as a possible landmark for targeting. We retrospectively evaluated the relationship between the obtained thalamotomy lesion and the ipsilateral superior thalamic vein (STV). A total of 36 patients (25 ET and 11 PD) who underwent MRgFUS treatment were evaluated, and the STV was studied with susceptibility weighted imaging (SWI) sequences. Based on the axial SWI images, the distance between the STV and the center of the lesion at the presumed site of the VIM was measured in follow-up MRI images one month after treatment. Statistical analysis shows that there is a correlation between the STV and the presumed site of the VIM. The STV visible in SWI could be used as an additional, real-time, and patient-specific anatomical landmark for VIM identification during MR examination and just before and during FUS treatment.

10.
Phys Med Biol ; 69(2)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38100845

RESUMO

Objective.Magnetic resonance imaging-guided focused ultrasound surgery (MRgFUS) is a non-invasive thermal ablation method that involves high-intensity focused ultrasound surgery (FUS) and Magnetic Resonance Imaging for anatomical imaging and real-time thermal mapping. This technique is widely employed for the treatment of patients affected by essential tremor (ET) and Parkinson's disease (PD). In the current study, functional near-infrared spectroscopy (fNIRS) was used to highlight hemodynamics changes in cerebral cortex activity, during a simple hand motor task, i.e. unimanual left and right finger-tapping, in ET and PD patients.Approach.All patients were evaluated before, one week and one month after MRgFUS treatment.Main results.fNIRS revealed cerebral hemodynamic changes one week and one month after MRgFUS treatment, especially in the ET group, that showed a significant clinical improvement in tremor clinical scores.Significance.To our knowledge, our study is the first that showed the use of fNIRS system to measure the cortical activity changes following unilateral ventral intermediate nucleus thalamotomy after MRgFUS treatment. Our findings showed that therapeutic MRgFUS promoted the remodeling of neuronal networks and changes in cortical activity in association with symptomatic improvements.


Assuntos
Tremor Essencial , Doença de Parkinson , Humanos , Projetos Piloto , Tremor Essencial/terapia , Tremor Essencial/cirurgia , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/terapia , Imageamento por Ressonância Magnética/métodos , Tálamo/cirurgia , Resultado do Tratamento
11.
Animals (Basel) ; 13(13)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37443998

RESUMO

The evaluation of the performance levels in athletic horses is of major importance to prevent sports injuries. Raman spectroscopy is an innovative technique that allows for a rapid evaluation of biomolecules in biological fluids. It also permits qualitative and quantitative sample analyses, which lead to the simultaneous determination of the components of the examined biological fluids. On the basis of this, the Raman spectroscopy technique was applied on serum samples collected from five Italian Saddle horses subjected to a standardized obstacle course preceded by a warm-up to evaluate the applicability of this technique for the assessment of central and peripheral fatigue in athletic horses. Blood samples were collected via jugular venipuncture in a vacutainer tube with a clot activator before exercise, immediately after exercise, and 30 min and 1 h after the end of the obstacle course. Observing the obtained Raman spectra, the major changes due to the experimental conditions appeared in the (1300-1360) cm-1 and (1385-1520) cm-1 bands. In the (1300-1360) cm-1 band, lipids and tryptophan were identified; in the (1385-1520) cm-1 band, leucine, glycine, isoleucine, lactic acid, tripeptide, adenosine, and beta carotene were identified. A significant effect of exercise was recorded on all the sub-bands. In particular, a change immediately after exercise versus before exercise was found. Moreover, the mean lactic concentration was positively correlated with the Raman area of the sub-band assigned to lactic acid. In this context, the application of Raman spectroscopy on blood serum samples represents a useful technique for secondary-structure protein identification to investigate the metabolic changes that occur in athletic horses during physical exercise.

12.
Biomedicines ; 11(12)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38137349

RESUMO

Electromagnetic radiation emitted by commonly used devices became an issue for public health because of their harmful effects. Notably, 2.45 GHz electromagnetic radiation exposure has been associated with DNA damage and alterations in the central nervous system. We here investigated the effects of 2.45 GHz electromagnetic radiation on cell redox status by using human SH-SY5Y neuroblastoma cells, which were differentiated to neuronal-like cells, and peripheral blood mononuclear cells (PBMCs), which were exposed to an antenna emitting 2.45 GHz electromagnetic radiation for 2, 24, and 48 h. We evaluated cell viability and mitochondrial activity alterations by measuring reactive oxygen species (ROS), mitochondrial transmembrane potential (ΔΨm), NAD+/NADH ratio, mitochondrial transcription factor A (mtTFA), and superoxide dismutase 1 (SOD1) gene transcript levels. We also investigated apoptosis and autophagy, evaluating B-cell lymphoma 2 (BCL2), BCL2-associated X protein (BAX), and microtubule-associated protein 1A/1B-light chain 3 (LC3) gene transcript levels. Cell viability was significantly reduced after 24-48 h of exposure to radiation. ROS levels significantly increased in radiation-exposed cells, compared with controls at all exposure times. ΔΨm values decreased after 2 and 24 h in exposed SH-SY5Y cells, while in PBMCs, values decreased soon after 2 h of exposure. Alterations were also found in the NAD+/NADH ratio, mtTFA, SOD1, LC3 gene expression, and BAX/BCL2 ratio. Our results showed that neuron-like cells are more prone to developing oxidative stress than PBMCs after 2.45 GHz electromagnetic radiation exposure, activating an early antioxidant defense response.

13.
Expert Rev Med Devices ; 20(4): 313-327, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36919481

RESUMO

AIM: The aim of the present study was to propose the clinical efficacy of the different dentin matrix obtained from three devices (BonMaker, Tooth Transformer, and Smart Dentin Grinder) and to show their morphological, physical, and biochemical characteristics using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) spectroscopy, and Raman spectroscopy. RESEARCH DESIGN AND METHODS: The study included 70 patients who underwent bone augmentation using the BonMaker, Tooth Transformer, and Smart Dentin Grinder devices. In addition, 84 implants were placed. Furthermore, four samples, one for each device and one non-demineralized control, were analyzed with scanning electron microscopy (SEM), energy-dispersive X-ray analysis, and Raman spectroscopy. RESULTS: In all patients, augmentation of bone defects with ground dentin matrix was successful, and implants showed correct osseointegration. The morphological organization, the chemical composition, and the presence of organic molecules in the dentin samples processed by the three different devices were demonstrated using SEM, energy-dispersive X-ray analysis, and Raman spectroscopy. CONCLUSIONS: Comparing BonMaker, Tooth Transformer, and Smart Dentin Grinder devices in our practice, we concluded that these systems, even with different structural and chemical differences of the dentin granules, have a comparable potential for obtaining regenerative material from the patient's own teeth.


Assuntos
Materiais Biocompatíveis , Dentina , Humanos , Dentina/química , Microscopia Eletrônica de Varredura , Osso e Ossos , Resultado do Tratamento
14.
Artigo em Inglês | MEDLINE | ID: mdl-35805332

RESUMO

Magnetic resonance (MR) systems are used in academic research laboratories and industrial research fields, besides representing one of the most important imaging modalities in clinical radiology. This technology does not use ionizing radiation, but it cannot be considered without risks. These risks are associated with the working principle of the technique, which mainly involves static magnetic fields that continuously increase-namely, the radiofrequency (RF) field and spatial magnetic field gradient. To prevent electromagnetic hazards, the EU and ICNIRP have defined workers' exposure limits. Several studies that assess health risks for workers and patients of diagnostic MR are reported in the literature, but data on workers' risk evaluation using nuclear MR (NMR) spectroscopy are very poor. Therefore, the aim of this research is the risk assessment of an NMR environment, paying particular attention to workers with active implantable medical devices (AIMDs). Our perspective study consisted of the measurement of the static magnetic field around a 300 MHz (7 T) NMR research spectrometer and the computation of the electric field induced by the movements of an operator. None of the calculated exposure parameters exceeded the threshold limits imposed by legislation for protection against short-term effects of acute occupational exposure, but our results revealed that the level of exposure exceeded the action level threshold limit for workers with AIMD during the execution of tasks requiring the closest proximity to the spectrometer. Moreover, the strong dependence of the induced electric field results from the walking speed models is shown. This case study represents a snapshot of the NMR risk assessment with the specific goal to increase the interest in the safety of NMR environments.


Assuntos
Campos Eletromagnéticos , Exposição Ocupacional , Campos Eletromagnéticos/efeitos adversos , Humanos , Campos Magnéticos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Exposição Ocupacional/análise , Ondas de Rádio
15.
Physiol Behav ; 250: 113781, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35314176

RESUMO

During shearing, animals' welfare is adversely affected and acute stress occurs. Once animal perceives a threat, it develops behavioral, autonomic, endocrine or immune responses to maintain homeostasis. This study aimed to investigate the usefulness of eye temperature assessment by infrared thermography (IRT) to evaluate acute stress response in sheep undergoing a shearing procedure. From each animal, blood sampling, rectal and eye temperature assessment were performed before shearing (TPRE), 5 (TPOST5) and 60 (TPOST60) minutes after the end of shearing procedure. On blood samples the serum cortisol concentrations were evaluated. Rectal temperature (TRECTAL) was measured using a digital thermometer. Thermographic acquisitions of eye temperature were performed from the eye total area (TEYE) and from three regions of interest (lateral canthus, TROI-1; central cornea, TROI-2; medial canthus, TROI-3). One-way analysis of variance showed a significant increase of serum cortisol concentration, TRECTAL, TEYE and TROI-3 (p < 0.001). Serum cortisol was positively correlated with TRECTAL and TROI-3 at TPOST5 and TPOST60. TRECTAL resulted positively correlated with TROI-3 at TPRE, TPOST5 and TPOST60. Agreement between TRECTAL and each eye temperature considered (TEYE, TROI-1, TROI-2, TROI-3) has been shown by Bland-Altman plots at each time point of monitoring period. The findings obtained in the current survey suggest that the medial canthus is the most suitable region for eye temperature measurement to asses stress response in animals. Moreover, this study highlighted the usefulness of IRT as an immediate and non-invasive physiological measure to assess stress response in sheep.


Assuntos
Hidrocortisona , Termografia , Animais , Temperatura Corporal/fisiologia , Ovinos , Temperatura , Termografia/métodos , Termômetros
16.
J Equine Vet Sci ; 108: 103820, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34798171

RESUMO

Raman spectroscopy is an inelastic light-scattering phenomenon that provides vibrational spectrum that contains information relative to chemical bonds and symmetry of a specific molecule, allowing the quali-quantitative simultaneous determination of several components in the biological fluids. Raman spectroscopy measurement returns a spectrum over a wavenumber range constituted by several bands representing biomarkers according to investigated biological matrices. In literature, it has been reported that at the frequencies inside the (1,300-1,360) cm-1 total lipids, and tryptophan have been identified. On the basis of that, the aim of the present study was to compare the serum concentration of total lipids and tryptophan in horses subjected to a standardized obstacle course, in comparison with the data obtained in the (1,300-1,360) cm-1 band. At this purpose, five clinically healthy and regularly trained Italian Saddle horses aged between 8, and 10 years old performed with the same rider an obstacle course of 350 m/min with twelve 1.30 m high jumps preceded by warm-up. Blood samples were collected by means of jugular venipuncture into a vacutainer tubes with clot activator at rest, after the exercise, and 30 minutes after the end of exercise. A high correlation was observed between the area of total lipids and tryptophan in the (1,300-1,360) cm-1 band and their serum concentrations in all experimental conditions. Our preliminary results give a hint to study the exact correspondence between the area that identify these parameters in Raman spectrum and their serum concentration in athletic horses.


Assuntos
Condicionamento Físico Animal , Esportes , Animais , Cavalos , Lipídeos , Análise Espectral Raman , Triptofano
17.
Animals (Basel) ; 12(10)2022 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-35625121

RESUMO

In veterinary medicine, the gold standard for assessing body temperature is rectal temperature assessment. Considering that this procedure is stressful for many species, in particular for cats, it could be clinically important to consider an alternative approach for the monitoring of core body temperature. The aim of this study was to test if cutaneous temperature measurements by means of different infrared thermometers are in agreement with the most commonly used method for body temperature measurement in cats. The cutaneous temperature was recorded in the jugular, shoulder, rib, flank, and inner thigh, using three different non-contact infrared thermometers (IR1, IR2, and IR3) in 20 cats. The cutaneous temperature was then compared to the rectal temperature, recorded by means of a digital thermometer. The obtained data indicated that the cutaneous temperature recorded by the infrared thermometers was not in agreement with the data recorded by the digital thermometer in the rectum. In cats, the use of non-contact infrared thermometers gave no reproducible or constant data to justify their application for the recording of body temperature instead of rectal temperature recording. In addition, the infrared temperature measurement devices generated results that were not in good agreement among themselves, providing a novel result of clinical importance.

18.
J Clin Med ; 11(5)2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35268494

RESUMO

The genetic and histopathological features of the cornea of a Polish patient with Gelatinous Drop-like Corneal Dystrophy (GDCD) and the molecular composition with Raman spectroscopy of corneal deposits were examined. A 62 year-old Polish woman was diagnosed with GDCD and underwent penetrating corneal transplant. A blood sample was collected, and genetic analysis was performed. The cornea was processed for light microscopy and Raman analysis. The genetic exam revealed a previously undescribed homozygous 1-base pair deletion in exon 1 of TACSTD2 gene (c.185delT), resulting in a frame shift causing a premature stop codon. When compared with a control cornea, in GDCD cornea stained with PAS evident deposits were present over the anterior stroma, with apple green birefringence under polarized light. Raman spectroscopy showed peculiar differences between normal and GDCD cornea, consisting in peaks either of different height or undetectable in the normal cornea and related to amyloid. The possible causative role of the novel mutation was discussed and Raman spectroscopy as a further morphological tool in the evaluation of corneal dystrophies, characterized by the deposition of abnormal materials, was suggested.

19.
Diagnostics (Basel) ; 11(7)2021 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-34359362

RESUMO

Celiac disease (CD) is diagnosed by a combination of specific serology and typical duodenal lesions. The histological confirmation of CD, mandatory in the majority of patients with suspected CD, is based on invasive and poorly tolerated procedures, such as upper gastrointestinal endoscopy. In this study we propose an alternative and non-invasive methodology able to confirm the diagnosis of CD based on the analysis of serum samples using the Raman spectroscopy technique. Three different bands centered at 1650, 1450 and 1003 cm-1 have been considered and the A1450/A1003 and A1650/A1003 ratios have been computed to discriminate between CD and non-CD subjects. The reliability of the methodology was validated by statistical analysis using receiver operating characteristic (ROC) curves. The Youden index was also determined to obtain optimal cut-off points. The obtained results highlighted that the proposed methodology was able to distinguish between CD and non-CD subjects with 98% accuracy. The optimal cut-off points revealed, for both the A1450/A1003 and A1650/A1003 ratios, high values of sensitivity and specificity (>95.0% and >92.0% respectively), confirming that Raman spectroscopy may be considered a valid alternative to duodenal biopsy and demonstrates spectral changes in the secondary structures of the protein network.

20.
J Equine Vet Sci ; 96: 103319, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33349414

RESUMO

Raman spectroscopy is a rapid qualitative and quantitative technique that allows the simultaneous determination of several components, both biomolecules both chemical compounds, in the biological fluids to assess the metabolic status. In this study, the serum composition was evaluated in regularly trained athletic horses using Raman spectroscopy to identify biomarkers of sports performance. Five clinically healthy and regularly trained Italian Saddle horses were subjected to a standardized obstacle course (350 m/minute; eleven 1.25 high jumps) preceded by a warm-up. On the collected sera, at rest, immediately after exercise, 30 minutes, and 1 hour after the end of the exercise Raman measurements were performed using a diode laser with the excitation wavelength of 785 nm. The analysis of the obtained spectra allowed the identification of peaks and bands different in position and intensity among the experimental conditions. The acquired spectra, obtained from horse sera collected during the experimental protocol, were visually similar, except for the large band detected in the 1,250-1,800 cm-1 range. The spectral intensity of the Raman spectrum decreased after training and 30 minutes after the end of exercise respect to the before exercise value, to come to the basal value after 60 minutes the end of the exercise. In conclusion, we can claim the ability of Raman spectroscopy to reveal the metabolic status of horses after physical exercise.


Assuntos
Condicionamento Físico Animal , Esportes , Animais , Biomarcadores , Cavalos , Análise Espectral Raman
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA